STOPPING THE ENGINE
To stop the engine, proceed as follows:
1. Disconnect all devices connected to the generator, then disable the ECON mode.
2. Allow the generator to operate at idle for 1-2 minutes for the alternator to cool down.
3. Set the engine switch to OFF (for model KSB 21i S, the engine switch is combined with the fuel valve handle)
.
Ensure that the devices are in good condition before connecting them to the generator. If the connected device
suddenly stopped working, immediately disconnect the load on the emergency stop switch, disconnect the device
and check it out.
Do not allow the simultaneous connection of two or more devices.
To run multiple devices generator needs more power. Devices
should be connected one by one according to their maximum
permissible power. Do not connect the load in the first 3 minutes
after starting the generator.
ATTENTION - DANGER!
DISCONNECT ALL THE DEVICES BEFORE STOPPING THE GENERATOR!
Do not stop the generator, if there are connected devices.
This may lead generator down!
ATTENTION - DANGER!
Tip: When starting the engine, with the ECON “ON”, and there is
no load on the generator:
IMPORTANT!
- In ambient temperature below 0°С (32°F), the engine will run at the rated r/min (4500r/min) for
5 minutes to warm up the engine.
- In ambient temperature below 5°С (41°F), the engine will run at the rated r/min (4500r/min) for
3 minutes to warm up the engine.
- The ECON unit operates in normal mode after the specified period of time, while the mode switch is
in the «ON» position
When using the generator be careful!
You can use the generator if the voltmeter shows the value of 230V
+/- 10% (50 Hz).
IMPORTANT!
fill to here
FUEL TANK VENT
For models KSB 21i S, KSB 31iE S, the fuel tank cap is provided
with a vent for sealing the fuel tank. The ventilation lever should
be used; leave the ventilation lever in the “OFF” position to
reduce the possibility of fuel leakage.
Fuel tank cap
Open
Closed
Ventilation lever
ENGINE START
- Check oil level.
- Check fuel level.
- For models KSB 21i S, KSB 31iE S
open the vent on the fuel cap to the “ON”
position
(see img.)
.
-
Turn the air choke control knob to the “START” (Close) position
, for model KSB 21i S, turn the
Multifunctional engine switch 3 in 1 to the “START” position.
-
Turn the fuel valve handle to the “ON” position (OPEN).
(for models
KSB 21i, KSB 35i, KSB 31iE S).
- Pull the manual starter until a slight resistance is felt, then pull it toward you relatively sharply.
- Slowly turn the manual starter by hand, do not release it abruptly.
- For generators with electric starters, turn the key to the START position and hold it in this position for a few seconds
until the engine starts. Release the start key for it to return to the “ON” position.
-
Turn the air choke control knob to the “RUN” (Open) position
, for model KSB 21i S turn the
Multifunctional engine switch 3 in 1 to the “RUN” position.
- Allow the generator to run idle for approx. 1-2 minutes.
- Connect the devices you need to the generator outlets.