background image

INTRODUCTION

SAFETY INFORMATION

1

Thank you for your purchase of

  K&S  Basic 

products. This manual contains a brief description of safety, use 

and debugging. More information can be found on the official manufacturer’s website in the support section:

 

ks-power.de/betriebsantleitungen.

You can also go to the support section and download the full version of the manual by scanning the QR code, or on 

the website of the official importer of 

K&S Basic

 products:

 www.ks-power.de/en

.

Manufacturer reserves the right to make alterations into the generators, which may not be reflected in this manual. 

Pictures and photos of the product may vary from its actual appearance. At the end of this manual, You may find 

contact information which you are free to use in case of any issues occurrence.
All data, specified in this operation manual is the most up to date for the moment of its publishing. The current list of 

service centers you can find at the website of official importer: 

www.ks-power.de/en

.

Do not use the generator in rooms with poor ventilation or in conditions of excessive humidity. Do not place the gen-

erator in water or on moist soil. Do not expose the generator to rain, snow, as well as to direct sunlight for a long time. 

Place the generator on a flat, hard surface, away from flammable liquids/gases (at a minimum distance of 1 m). Keep 

unauthorized persons, children, and animals away from work area. Wear safety shoes and gloves.

We care about the environment, therefore, we consider it expedient to savepaper and 

leave in print a short description of the most important sections.

Failure to follow the recommendations marked with this sign may 

lead to serious injury or death of the operator or third parties.

ATTENTION – DANGER!

Useful information while operating the machine.

IMPORTANT!

Be sure to read the full version of the manual before

getting started!

ELECTRICAL SAFETY

1.1

The generator produces electricity that may lead to an electric shock while neglecting compliance regulations. All 

connecting the generator to the network must be made by certified electrician in accordance with all electrical rules 

and regulations. Connect the generator to the protective ground before operation. Wires with damaged or spoiled 

insulation should be replaced. You should also replace worn, damaged or rusty contacts.

The device generates electricity. Follow safety precautions to 

avoid electric shock.

ATTENTION – DANGER!

Safety symbols and description of inscriptions can be found in the full electronic version.

Be careful. Do not operate the generator, if you are tired,

under the influence of drugs or alcohol. Inattention may

cause a serious injury.

ATTENTION – DANGER!

www.ks-power.de/en

   

|

    17

Содержание KSB 21i

Страница 1: ...Please read this manual carefully before use OWNER S MANUAL Inverter Generator KSB 21i S KSB 21i KSB 35i KSB 31iE S EN ...

Страница 2: ...nerator on a flat hard surface away from flammable liquids gases at a minimum distance of 1 m Keep unauthorized persons children and animals away from work area Wear safety shoes and gloves We care about the environment therefore we consider it expedient to savepaper and leave in print a short description of the most important sections Failure to follow the recommendations marked with this sign ma...

Страница 3: ...nder volume cm3 79 5 119 212 149 8 Engine type gasoline 4 stroke cycle engine Outlets 2х16А Power factor cosφ 1 Fuel tank volume l 4 0 10 13 6 Crankcase volume l 0 4 0 4 0 6 0 8 Engine start ручний manual manual manual electro Noise level LPA 7m LWA dB 68 93 70 95 71 96 69 96 Dimensions L W H mm 535 335 480 455 385 435 520 440 470 585 350 490 Lithium battery Ah 4 5 Net weight kg 20 21 34 30 Protec...

Страница 4: ...control switch ECON 7 Grounding 8 Elactrostart for model KSB 31iE S 9 16A outlets MODELS KSB 21i S KSB 31iE S 1 Transport handles 2 Fuel tank cap 3 Control panel 4 Starter 5 Maintenance panel 6 Ventilation grille 7 Silencer MODELS KSB 21i KSB 35i 1 Starter 2 Frame 3 Fuel tank cap 4 Maintenance panel in another side 5 Ventilation grille 6 Silencer 1 Switch 2 Economy control switch ECON 3 Voltage in...

Страница 5: ...gine oil is insufficient Add oil and restart IMPORTANT TERMS OF USE 4 When starting operating the generator it s recommended to ground it Before starting the unit remember that the total power of consumers connected should not exceed the rated capacity of the generator TYPES OF CONSUMERS AND INRUSH CURRENT Consumers electrical devices connected to the generator are divided into active and reactive...

Страница 6: ...ult you get less fuel consumption and noise OFF When the ECON switch is turned to OFF the engine runs at the rated speed 4500r min regardless of whether is a load connected or not Tip The overload indicator light may come on for a few seconds at first when using electric devices that require a large starting current such as a compressor or a submergible pump However this is not a malfunction IMPOR...

Страница 7: ...are higher than standard atmospheric conditions Additionally the load must be reduced when using in a confined area as generator cooling is affected Recommended engine oil SAE 10W 30 SAE 10W 40 Recommended engine oil grade API Service SE type or higher Motor oil quantity see specifications table 1 Unscrew the oil dipstick and wipe it out with a clean cloth 2 Insert the dipstick without screwing it...

Страница 8: ... the engine The ECON unit operates in normal mode after the specified period of time while the mode switch is in the ON position When using the generator be careful You can use the generator if the voltmeter shows the value of 230V 10 50 Hz IMPORTANT FUEL TANK VENT For models KSB 21i S KSB 31iE S the fuel tank cap is provided with a vent for sealing the fuel tank The ventilation lever should be us...

Страница 9: ...t is on 5 Turn on any electric devices Before operating the generator connect ground wire to ground terminal Please consult with a specialist before using the ground terminal IMPORTANT IMPORTANT Tip Make sure to ground the generator When the electric device is earthed the generator must be grounded too IMPORTANT WARNING Tip The ECON must be turned OFF to increase engine speed to rated rpm If the g...

Страница 10: ... DC protector turns off automatically if current above the rated flows during battery charging To restart charging the battery turn the DC protector on by pressing its button to ON If the DC protector turns off again stop charging the battery immediately and contact the point of sale Never smoke or interrupt battery connections to the generator while the battery is being charged Sparks can cause b...

Страница 11: ... every 25 operating hours If the engine is often running in dusty or other harsh conditions please clean the air filter every 10 hours If you missed the maintenance time perform it as soon as possible to save the generator engine Stop the engine before servicing Place the generator on a flat surface and remove the spark plug cap to prevent starting the engine Do not run the engine in a poorly vent...

Страница 12: ...mmediately after stopping the engine The oil is hot and should be handled with care to avoid burns ATTENTION DANGER Do not tilt the generator while adding oil to the engine This can lead to overfilling and damage to the engine ATTENTION DANGER fill to here It is necessary to check the air filter from time to time and clean any contaminations Regular air filter maintenance is necessary to maintain ...

Страница 13: ...void touching the engine and muffler while they are still hot with any part of your body or clothing during inspection or repair MUFFLER SCREEN AND SPARK ARRESTER TECHNICAL MAINTENANCE 13 1 Remove the screws and then pull outward on the areas of the cover 2 Loosentheboltandremovethemufflercap themufflerscreenandsparkarrester 3 Clean the carbon deposits on the muffler screen and spark arrester usin...

Страница 14: ...pose your feet under the generator To prevent damage to the environment separate generator and battery from ordinary waste and recycle them in the safest way passing a special place for disposal Potential faults and troubleshooting methods as well as average device capacities can be found in thefull version of the manual WARRANTY SERVICE TERMS 18 The international manufacturer warranty is 1 year T...

Страница 15: ......

Страница 16: ......

Страница 17: ...tional Poland Sp z o o Polen Warczawska 306B 05 082 Stare Babice www ks power pl info pl dimaxgroup de Україна ТОВ Техно Трейд КС вул Електротехнічна 47 02222 м Київ Україна www ks power com ua sales ks power com ua Россия ТД Рус Энержи К С 129090 г Москва проспект Мира д 19 стр 1 эт 1 пом 1 комн 6б офис 99В www ks power ru info ks power ru ...

Отзывы: