TECHNICAL DESCRIPTION flowIQ® 3100
12
Kamstrup A/S • Technical Description • 5512
-
1242_B1_GB • 05.2015
4
Confi
guration
Configuration
KK
LLL MMM N P R S T
□□
□□□
□□□
□
□
□
□
□
Target date
01
Average time of max
.
values
2 minutes
(1…120 min.)
002
Customer label
2005
-MMM
MMM
Leakage message limit
OFF
0
Flow continuously > 0
.5%
of Q3
1
Flow continuously > 1
.
0% of Q3
2
Flow continuously > 2
.
0% of Q3
3
Flow continuously > 0
.25%
of Q3
4
Flow continuously > 0
.
1% of Q3
5
Pipe burst limit
OFF
0
Flow > 5 %
of Q3 for 30 minutes
1
Flow > 10 % of Q3 for 30 minutes
2
Flow > 20 % of Q3 for 30 minutes
3
Optional register in data logger
* Reccommended for ’Drive-by’ ** Reccommended for ’Fixed network’
Meter reading target date (monthly)
1
Max. flow during last month
2
Monthly target volume/
Min.temp.water, daily
/Time weighted average temp. meter,
daily
**
3
Monthly max. flow/Average temp.water,daily/Time weighted aver. temp. meter,daily
**
4
Monthly target volume /
Min. water temp. monthly
/ Min. temp. meter,latest month
*
5
Monthly target vol
ume/
Min. water temp., monthly
/Max. temp. meter, latest month
*
7
Daily max. flow /
Min.temp.water, daily
/ Time weighted average temp. meter, daily
**
9
Measuring the water temperature is only valid for meter sizes 1.6 and 2.5m
3
/h
Display resolution
00001 m³
0
00000
.
1 m³
1
00000
.
01 m³
2
00000
.
001 m³
3
Encryption level
No encryption
0
Utility encryption (only available for selected markets)
2
Encryption with separately forwarded key
3
Unless otherwise stated in the order
,
Kamstrup supplies the following:
01 002 000 1 3
5
3 3
Содержание flowIQ 3100
Страница 1: ...Tecnical Description flowIQ 3100 Water Meter ...
Страница 2: ...TECHNICAL DESCRIPTION flowIQ 3100 2 Kamstrup A S Technical Description 5512 1242_B1_GB 05 2015 ...