Pulse Interface for flowIQ® 3
100 /
MULTICAL® 21
Pulse Interface
, type 66
-
99
-143,
is used during calibration and verification in test stands with pulse
interface. The optical reading head is retained on flowIQ® 3100 by means of a transparent plastic holder
(Optical support, type 6561
-
331). Data from flowIQ®
3100 is read by the optical reading head, and in the
pulse interface unit converted into high
-
resolution volume pulses which can be registered by a pulse
receiver. When the optical reading head is removed, it takes 9 hours, before the meter
returns to normal
mode.
Pulse Interface, type 66-99-143 , with Optical Support type 6561-331 on flowIQ® 3100
Supply:
3.5
-30 VDC
<
15 mA
Standby:
<
0.2 mA
Pulse width
:
= 3.9ms
Frequency: Max frequency of 128 Hz
Meter size
Q3 [m
3
/h]
:
Volume
[pulses/liter
]
1
.6 & 2.5
100
4
.
0
50
6.
3
25
10
12
.5
16
12
.5
25
6