TECHNICAL DESCRIPTION flowIQ® 3100
26
Kamstrup A/S • Technical Description • 5512
-
1242_B1_GB • 05.2015
If the info code DRY is active, it will immediately appear in the display and from readings via the optical eye.
In order to avoid false alarms due to short
-term air build-
up in the meter, the info code DRY is not added to
the relevant registers until it has been continuously active for 30 minutes.
DRY is saved with a date stamp in both the daily register for 460 days and the monthly register for 36
months. Furthermore, it is saved in the info code register of the latest 50 info code events. Together with
the info code event, a time indicator with 7 time intervals (which indicates how long the info code has been
active) is registered.
Correspondingly the info code DRY is not added to the Wireless M
-
Bus signal until it has been continuously
active for 30 minutes. Furthermore, if the info code DRY has been active within the latest 30 days, a time
indicator with 7 time intervals indicates in the Wireless M
-
Bus signal how long the info code has been
active
.
Infokode – REVERSE
This info code indicates that the water in the meter flows in the wrong directio
n
.
Info code REVERSE is activated when the water runs backwards in the meter
at a flow which numerically
exceeds Q1 for 5 consecutive minutes.
The code disappears from the display when the water is stagnant, or again runs in the correct direction in
the meter. It can take up to 64 until the info code disappears.
The alarm REVERSE is saved with a date stamp in both the daily register for 460 days and in the monthly
register for 36 months. Furthermore, it is saved in the info code register of the latest 50 info code events.
Together with the info code event a time indicator with 7 time intervals, which indicates how long the info
code has been active, is registered.
The Wireless M
-
Bus signal includes the code REVERSE. If the code REVERSE is active or has been
active
within the latest 30 days, a time indicator with 7 time intervals will indicate how long the info code has
been active
.
Reverse flow is counted and logged
in a separate internal register in the meter and can only be read on a
monthly basis. If a me
ter
has been
incorrectly installed
(with reverse flow direction)
for a longer period,
the
reverse
volume could be read in the monthly logger. This log is
,
similar to the legal log, an absolute log
–
which means that the total
reverse consumption
for the past month are shown in the log at the end of the
month. So even if the fault is corrected, the total reverse consumption
can not be seen until
the end of the
month.
The total reverse volume is measured and recorded whether the info code is being activated or not.
It should be emphasized that the register for backwards volume is NOT covered by the type approval, and
therefore not approved for billing purposes.
The register can only be read via the optical eye with LogView.
The legal volume register, V1, and
thus the meter's target data is not affected by the reverse flow.
Info code – RADIO OFF (transport mode)
This info code is active in the display when
the
water meter leaves Kamstrup A/S, and indicates,
that
the meter is still in ‘transport mode’ and that the built
-in Wireless M-
Bus radio transmitter has not yet
been activated.
In transport mode the meter displays info codes, if any, but they are not logged into the corresponding
registers, and they are not
added to the corresponding hour counters.
The Wireless M
-
Bus radio transmitter is activated when water starts flowing and the meter has registered
approx
. 0.5 liters of water flow. The radio transmitter remains active.