flowIQ
®
3100 TECHNICAL DESCRIPTION
35
Kamstrup A/S • Technical Description • 5512
-
1242_B1_GB • 05.2015
9.5
Meter modes (settings)
The meter
ha
s 2 modes:
Meter mode:
Normal
Verification
Measuring cycle
(measurement/calculation)
4 s/32 s
0
.5 s/4 s
Display value
[m
3
]
[L]
Display dots, frequency
1 Hz
2 Hz
Mode, time out
No
Yes
Verification mode is only used by authorised laboratories during verification.
9.6
Normal mode
Normal mode is meant for normal operation
.
In normal mode the m
3
symbol
(volume unit) is displayed. Furthermore, the two square ‘dots’ at the
bottom right of the display shift every second.
The flow is measured every four seconds and new values (flow, volume, etc.) are calculated every 32
seconds
.
9.7
Verification mode
Verification mode is meant for verification of the meter.
In the display verification mode is indicated by the ‘L’ symbol (volume unit). In addition, the 2 dots at the
bottom right of the display are changing 2 times per second.
The flow is measured twice a second and new values (flow, volume, etc.) are calculated every four seconds.
When the meter switches to ‘verification mode’, the wireless M
-
Bus radio transmitter will be turned off. At
the same time a time
-
out starts. When th
e time-
out period has expired the meter switches back to normal
mode. The time
-
out period is 9 hours.
9.8
Legal changes outside seal
This paragraph describes the legal changes, which can be carried out without disassembling the meter and
thereby breaking the legal seal.
All legal changes are fully traceable in an adjust log, which cannot be deleted. The number of legal changes
appears from the display (see paragraph 8.
7
.5). Maximum 9 changes are possible.
The adjust log can only be deleted if the meter is disassembled and the legal seal is broken.
It appears from the meter’s software version whether a specific meter can be reset outside the legal seal.
See support of legal changes below
:
SW revision
Re-
adjustment
Reset
A1
B1 – F1
•
G1 – …
•
•
•
= Supported