TECHNICAL DESCRIPTION flowIQ® 3100
16
Kamstrup A/S • Technical Description • 5512
-
1242_B1_GB • 05.2015
6
Pressure loss
According to OIML R49 maximum pressure loss must not exceed 0.63 bar (0.063 MPa) in range Q1 to Q3.
The pressure loss in a meter increases with the square of the flow and can be stated as:
p
kv
Q
∆
×
=
where
:
Q = volume flow rate [m
3
/h]
kv = volume flow rate at 1 bar (0.1 MPa) pressure loss
Δp = pressure loss [bar]
Pressure loss table
Graph
Q3[m
3
/h]
Nom.
diameter
[mm]
K
v
Q at 0
.63 bar
[m
3
/h]
B
1
.6 & 2.5
DN15
& DN20
4
.
3
3
.
4
C
4
.0 & 6.
3
DN25
13
10
D
10
DN40
28
22
E
16
DN50
37
29
F
25
DN65
102
81
Pressure loss diagram