TECHNICAL DESCRIPTION flowIQ® 3100
44
Kamstrup A/S • Technical Description • 5512
-
1242_B1_GB • 05.2015
11.5.1
Description
Pulse output:
Type
Open Drain
Maximum input voltage
30V
Maximum current sink
27mA
On voltage
Vout < 0
.
3V @ 0
.
1mA current
Vout < 2V @ 27mA current
OFF condition
R > 6Mohm
The connection marked "
-
" must be connected to the receiver's GND level.
The
connection
marked "+" should be connected to a
pull-up resistor of an appropriate size,
so
that the maximum limits
,
shown in the table above
, are met
.