Power Supply Front Panel Controls
All of the Spirit controls and status indicator lights are located on the front
panel of the system as shown below. This section describes the function
of each control and indicator.
Power Off Button
Deenergizes the Spirit system and turns off the cooling fans and coolant
pump.
Power On Button/Indicator
Energizes the Spirit system and turns on the cooling fans and coolant
pump. Also illuminates to show that the system is energized.
AC Power Indicator
Illuminates when 3 phase power is applied to the Spirit system.
DC Power Indicator
Illuminates when then main contactor has been energized and D.C.
current is flowing through the torch.
Status Indicators
•
RHF Door Indicator
Illuminates when the RHF console door is closed securely. Remains
extinguished when the RHF console door is open.
•
Gas Console Indicator
Illuminates when the automatic gas console is operational. Remains
extinguished when there is a problem with the gas system. Check the
message screen on the automatic gas console for errors.
•
3 Phase Power Indicator
Illuminates when 3 phase power is satisfactory. Remains extinguished
when there is a problem with main 3 phase power to the system.
•
Coolant Flow Indicator
Illuminates when the coolant flow through the system is satisfactory.
Remains extinguished when the coolant flow through the system is
restricted.