Installation
Spirit200a User’s Manual Rev J
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
3-10
Torch Leads to Torch Base Connections
Perform the following steps to connect the torch leads to the torch base.
Note: When making hose connections, only tighten the brass fittings
enough to make water or gas seals. The fittings are subject
to damage if over tightened. Also, use two wrenches when
tightening the torch fittings to avoid damaging the torch
Torch Handle Installation
1. Route the torch leads through the torch handle. Note that the threaded
end of the torch handle mates with the torch base.
Torch Electrode/Coolant Supply Lead
•
Connect the torch electrode/coolant supply lead to the torch base as
shown.
Torch Coolant Return Lead
•
Connect the torch coolant return lead to the torch base as shown.
Note that the torch coolant return lead fitting has left hand threads.
Torch Nozzle Lead
•
Connect the torch nozzle lead to the torch base as shown.
Torch CTP Sensor Lead
•
Connect the torch CTP sensor lead to the torch base as shown.
10
11
12
13