Installation
Spirit200a User’s Manual Rev J
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
3-19
Initial Filling of the Torch Coolant Reservoir
Note: Never turn on the power supply before filling the torch
coolant reservoir with the proper coolant solution.
When handling coolant, it is recommended that you wear
nitrile gloves and safety glasses.
1. Remove the coolant reservoir cap and fill the reservoir with 2 gallons of
coolant solution.
2. Apply main power to the Spirit unit.
3. Depress and hold the green ON button on the Spirit control panel.
4. The coolant pump will begin pumping coolant fluid through the system.
The Coolant Flow LED will remain out until the coolant has filled the
entire system and begins flowing back into the tank. The coolant pump
will turn off if the coolant level drops below the minimum level inside
the reservoir. If this happens, add more coolant solution to the
reservoir and return to Step 3.
5. When the Coolant Flow LED illuminates, release the green ON switch.
The Spirit system should remain energized and continue pumping
coolant through the system.
6. Locate the small red push-button on top of the coolant
filter/deionization cartridge. Depress and hold the button until no air is
seen inside the clear filter housing.
7. Fill the reservoir with coolant solution until the coolant gauge indicates
full. Coolant should be added to the system any time the level drops
below half full.
8. Check for coolant leaks at all hose connections inside the power
supply, RHF console, and at the torch.