Important Statement 

1.

 

User shall be fully responsible for the maintenance and management of this product after 

purchasing this product.

 

2.

 

Even in the warranty period, warranty does not include the following:

 

a)

 

Damage or loss caused by error or rough using. 

b)

 

Damage  or  loss  caused  by  force  majeure  (such  as  fires,  earthquakes,  floods,  or 

lightning etc.). 

c)

 

Damage or loss caused by not meeting the conditions of use specified by the system, 

such as inadequate power supply, incorrect installation or environmental conditions do 

not meeting the requirements. 

d)

 

Damage or loss caused by not used the system in the initial buy region. 

e)

 

Damage or loss caused by the system purchased not by Kaixin or its authorized dealer 

or agents. 

3.

 

Medical personnel qualified with professional qualifications only to use this system. 

4.

 

Do  not  modify  the  software  or

 

hardware  of  the  equipment  without  authorization  of  the 

manufacturer.

 

 

5.

 

In  any  case,  Kaixin  shall  not  be  liable  for  the  problems,  damages  or  losses  due  to 

re-installation, alteration or repair the system by non-Kaixin designated personnel. 

6.

 

This product is intended to provide clinical diagnostic data for the doctor.

 

The  doctor  shall  be  responsible  for  the  diagnostic  process.  Kaixin  shall  not  be  liable  for 

any problems arising out of the process. 

7.

 

Be sure to back up important data to external storage media, such as notebooks. 

8.

 

Due to operator’s error or abnormal condition causing the data stored in the internal system 

is lost, Kaixin is not responsible. 

9.

 

This  user’s  manual  contains  warnings  for  predictable  dangers.  Users  shall  also  exercise 

care at any time to be aware of the dangers unforeseen in this manual. Kaixin shall not be 

liable  for  the  damages  and  losses  arising  out  of  neglecting  to  follow  the  operation 

instructions herein described. 

10.

 

This  user’s manual shall be  furnished with  the machine so that managerial  and operating 

personnel  can  refer  to  it  any  time  as  necessary.

 

Once  the  managerial  personnel  of  the 

system changes, it shall hand over this user’s manual. 

11.

 

Deal with the exhausted product according to the local statute. 

12.

 

The maintenance and servicing of product shall be performed by the trained engineer or by 

Kaixin Electronic Instrument Co., Ltd. 

 

 

 

 

 

 

Содержание MSU3

Страница 1: ...KAIXIN MSU3 Full Digital Mechanical Sector Scanning Ultrasonic Diagnostic Instruments Vet User s Manual Xuzhou Kaixin Electronic Instrument Co Ltd...

Страница 2: ...esponsible for the safety reliability and performance in case of meeting all the following requirements 1 Assembly expansion readjustment improve and repair are all performed by professionals recogniz...

Страница 3: ...problems damages or losses due to re installation alteration or repair the system by non Kaixin designated personnel 6 This product is intended to provide clinical diagnostic data for the doctor The...

Страница 4: ...a potential danger or unexpected use condition that may result in light injury or property loss or affecting the use if not avoided 2 Safety Symbols Symbols Meaning Symbols Meaning Type B applied part...

Страница 5: ...lation and Check 5 5 1 System installation 6 5 2 Install Remove the battery 6 5 3 Connection to shutter release 7 5 4 Connection to power 7 5 5 Ultrasonic probe check before and after operation 7 5 6...

Страница 6: ...eeze 13 6 7 Image Data storage and viewing 13 6 7 1 Image data storage 13 6 7 1 1 Save image in B 2B mode 13 6 7 1 2 Save data in A mode 14 6 7 2 View image or data 14 Chapter 7 Fat thickness and Lean...

Страница 7: ...it approx 620g including battery and probe 1 2 Primary Functions 1 System preset function 2 Mode conversion function 3 Adjustment of near field far field total gain and dynamic range 4 Frequency conve...

Страница 8: ...ing ultrasonic diagnostic instruments Vet are composed of main unit and probe etc 2 2 Components name Figure MSU3 main unit sketch map 2 3 Function keys description SN Function keys Function 1 Image p...

Страница 9: ...Chapter 3 System Configuration 3 1 Standard Configuration 1 Main unit 1 unit 2 3 5MHz mechanical sector probe 1 PC 3 Power adapter 1 PC 4 Internal battery 1 PC 5 Power cable 1 PC 6 OTG U disk 1PC 7 V...

Страница 10: ...may result in explosion Warning Avoid using this equipment with high frequency electric knife high frequency therapy equipment or defibrillators and other electronic devices or may an electric shock...

Страница 11: ...nnect the grounding wire to any gas pipe or water pipe or it may cause bad grounding and danger of explosion 3 This equipment is not waterproof not use this equipment in place where liquid may into th...

Страница 12: ...ry Service personnel or operator can replace the battery Before replacing the battery please contact Kaixin Company replace the battery under the guidance of Kaixin Company Please use the battery prov...

Страница 13: ...heck before and after operation Before and after ultrasonic diagnosis to check if there are any exceptionally on the surface of the probe or cable jacket such as peeling cracks bulge or if the acousti...

Страница 14: ...possible damage or blockage 9 Clean the field and environment 5 6 2 Inspection after start up Check the following items after starting the machine 1 No abnormal voice strange smell and overheating app...

Страница 15: ...ystem Set menu 2 Press or key to move the cursor to Time item and then press or key to adjust the time 3 Press key to confirm the time setting and quit system setting interface 6 2 3 Probe protect tim...

Страница 16: ...ress key to confirm this setting and quit system setting interface Explanation The ear tag scanning function is to be upgraded 6 2 7 Menu time setting 1 Press key and then press key to enter System Se...

Страница 17: ...Repeatedly press key also to achieve the cycle conversion among the B A 2B mode 6 4 Image adjustment 6 4 1 Image adjustment in B 2B mode In B 2B mode and in real time status you can adjust images gain...

Страница 18: ...ress direction key to reduce far field gain so as to control the gain in far field region 3 After waitting for 5 30s Menu Time set in the System Set the parameters will be saved and exit the image adj...

Страница 19: ...e and in real time status press key to enter gain adjustment status 2 Press or key to adjust the gain within 27 90 3 After waitting for 5 30s Menu Time set in the System Set the parameters will be sav...

Страница 20: ...uary 14 2016 on the storage path U IMAGE save a 20160114 csv EXCEL spreadsheet 6 7 1 2 Save data in A mode 1 Insert OTG U disk into the Micro USB interface at the right side of main unit the lower lef...

Страница 21: ...propriate site of swine s back if necessary cut off the hair at the measurement site and wet the skin with hot water then apply light oil to wet the skin one minute or two in order to make good contac...

Страница 22: ...make good contact between swine skin and sound window The probe is placed against the skin of the swine and is kept perpendicular to the back move the probe gently make sure no air bubbles between the...

Страница 23: ...following table Glutaraldehyde based disinfectant Chemical Name Reagent Name Step Glutaraldehyde 2 4 Cidex Glutaraldehyde disinfectant Please refer to the instructions of the solution for details Warn...

Страница 24: ...ou may follow the recommended method by the disinfectant manufacturer to rinse 4 After finishing the rinsing use a sterilized cloth or gauze to wipe the water on the surface of probe Do not dry the pr...

Страница 25: ...g will shorten the battery life the full charged battery can be used about 5 hours 4 Battery is consumable the battery cycle life is based on the times of charge and discharge as unit When the use tim...

Страница 26: ...ch will lead to the leakage explosion or fire 12 Do not mixed use the battery together with one off battery such as dry battery or different capability or different model or different brand battery wh...

Страница 27: ...far field Control panel malfunction Turn off the machine and restart it 8 4 Periodic Safety Checks To ensure the system performance and safety it must be checked after using 1 year When check the inst...

Страница 28: ...nd corrosive gas 3 Shockproof measures have been taken inside the packing case to allow for transport by air railway land and sea The goods shall not be exposed to poor weather conditions like rain an...

Страница 29: ...zhou Jiangsu China Post Code 221004 Tel 86 516 87732932 87733758 Fax 86 516 87732932 87792848 Website http www kxele com E mail info kxele com Shanghai International Holding Corp GmbH Europe Eiffestra...

Отзывы: