background image

B

C

D

A

E

Hook

Connecting point of 

    refrigerant pipe

Connecting point of 

    refrigerant pipe

Drain point

(gas side)

(Liquid side)

4

Keep indoor unit, outdoor unit, power supply wiring and 

transmission wiring at least 1 meter away from televisions 

and radios. This is to prevent image interference and noise 

in those electrical appliances. (Noise may be generated 

depending on the conditions under which the electric wave 

is generated, even if 1 meter is kept.) 

 

CAUTION

-   There is enough room for installation and maintenance.

-   The ceiling is horizontal, and its structure can endure the weight 

    of the indoor unit.

-   The outlet and the inlet are not impeded, and the influence of 

    external air is the least.

-   The air flow can reach throughout the room.

-   The connecting pipe and drainpipe could be extracted out easily.

-   There is no direct radiation from heaters.

1.1    Installation place

1.2   

The dimension of the unit

The indoor unit should be installed in a location that meets the 

following requirements:

1.     INDOOR UNIT INSTALLATION

All the pictures in this manual are for explanation purpose only.

There may be slightly different from the air conditioner you 

purchased ( depend on model ). The actual shape shall prevail.

NOTE

>35mm

>1000mm

>3

5m

m

>3

5m

m

MODEL(

)

Btu/h

AA

BB

CC

DD

EE

30K

36K/42K/48K/55K

18K/24K

1650

1068

1285

675

675
675

235

235
235

1565

983

1200

220

220
220

Unit:mm

Unit:mm

1.3   Install the main body

     1    Installing    10  hanging screw bolts. (4 bolts)

O

O

Please refer to the following figures for positioning 4 screw bolts.

Evaluate the ceiling construction and please install with    10 

 hanging screw bolts.

The handling to the ceiling varies from the constructions,

consult the construction person for the specific condition.

-  Do keep the ceiling flat. Consolidate the roof beam to avoid 

   possible vibration.

-  Cut off the roof beam.

-  Strengthen the place that has been cut off, and consolidatethe 

   roof beam.

After the selection of installation location, position the refrigerant 

pipes, drain pipes,indoor & outdoor wires to the connection 

places before hanging up the machine.

The installation of hanging screw bolts.

6

kaisai.com

Содержание 12K

Страница 1: ...PE INSTALLATION MANUAL Ceiling And Floor Type Thank you verymuch for purchasingour air conditioner Before using yourair conditioner please read thismanual carefully andkeep it forfuture reference INST...

Страница 2: ...If used as MULTI unit please refer to the Installation operation manuals packed with outdoor unit...

Страница 3: ...and firm location which is able to withstand the set s weight If the strength is not enough or installation is not properly done the set will drop to cause injury The appliance shall not be installed...

Страница 4: ...es a distance of 1 meter may not be sufficient enough to eliminate the noise The appliance is not intended for use by young children or infirm persons without supervision Don t install the air conditi...

Страница 5: ...some models 1 on some models 1 1 2 on some models 2 on some models 6 Remote controller 7 Frame 8 Mounting screw ST2 9 0 C H 9 Alkaline dry batteries Am4 10 Remote controllermanual 11 Wirecontroller 12...

Страница 6: ...eets the following requirements 1 INDOOR UNIT INSTALLATION All the pictures in this manual arefor explanation purpose only There may be slightly different fromthe air conditioner you purchased depend...

Страница 7: ...squaretimber traversely over the roof beam then install thehanging screw bolts Inlaying or embeddingthe screw bolts Use embedding screwbold crock andstick harness Timber over thebeam Roof beam Ceilin...

Страница 8: ...may shorten the life of the air conditioner 9 Since drain flows out of the outdoor unit do not place under the unit anything which must be kept away from moisture Cannot be installed hanging from ceil...

Страница 9: ...atterns the wall height on the outlet side should be 1200mm or less 1 Installing outdoor unit 2 Drain work If drain work is necessary follow the procedures below Use drain plug for drainage If the dra...

Страница 10: ...il Precautions 3 1 Flaring the pipe end 1 Cut the pipe end with a pipe cutter 2 Remove burrs with the cut surface facing downward so that the chips do not enter the pipe 5 Check that the flaring is pr...

Страница 11: ...the check is complete wipe all soapy water off 7 Disconnect charging hose from gas stop valve s service port then fully open liquid and gas stop valves Do not attempt to turn valve rod byond its stop...

Страница 12: ...tion Gas pipe Keep piping as short as possible and slope it downwards at a gradient of at least 1 100 so that air may not remain trapped inside the pipe Keep pipe size equal to or greater than that of...

Страница 13: ...it body to wire the outdoor unit indoor units and the remote controller 11 The specification of power Minimum norminal cross sectional area of conductors Rated current of appliance A Nominal cross sec...

Страница 14: ...m according to the figure 1 When attaching the control box lid make sure not to pinch any wires After all wiring connections are done fill in any gaps in the casing wiring holes with putty or insulati...

Страница 15: ...ndensed of by the air conditioner have influenced your neighborhood Whether any of the refrigerant is leaked A protection feature prevents the air conditioner from being activated for approximately 3...

Страница 16: ...for product improvement Consult with the sales agency or manufacturer for details QSDLI 016AEN CE 16122500000090 20150122 t to change without prior notice for product ncy or manufacturer for details 1...

Отзывы: