2.1    Precautions for selecting the location

2.2    Figure of body size

2.     OUTDOOR UNIT INSTALLATION

1)   Choose a place solid enough to bear the weight and vibration of 

       the unit, where the operation noise will not be amplified.

2)   Choose a location where the hot air discharged from the unit or 

      the operation noise will not cause a nuisance to the neighbours 

      of the user.

3)   Avoid places near a bedroom and the like, so that the operation 

      noise will cause no trouble.

4)   There must be sufficient spaces for carrying the unit into and out 

      of the site.

5)   There must be sufficient space for air passage and no 

      obstructions around the air inlet and the air outlet.

6)   The site must be free from the possibility of flammable gas 

      leakage in a nearby place.

7)   Install units, power cords and inter-unit wire at least 3m away from 

      television and radio sets. This is to prevent interference to images 

      and sounds. (Noises may be heard even if they are more than 3m 

      away depending on radio wave conditions.)

8)   In coastal areas or other places with salty atmosphere of sulfate 

      gas, corrosion may shorten the life of the air conditioner.

9)   Since drain flows out of the outdoor unit, do not place under the 

      unit anything which must be kept away from moisture. 

Cannot be installed hanging from ceiling or stacked.

NOTE:

When operating the air conditioner in a low outdoor ambient 

temperature, be sure to follow the instructions described below.

-  To prevent exposure to wind, install the outdoor unit with its suction 

    side facing the wall.

-   Never install the outdoor unit at a site where the suction side may 

    be exposed directly to wind.

-   To prevent exposure to wind, it is recommended to install a baffle 

    plate on the air discharge side of the outdoor unit.

-   In heavy snowfall areas, select an installation site where the snow 

    will not affect the unit.

CAUTION

-  Construct a large canopy.

-  Construct a pedestal.

Install the unit high enough off the 

ground to prevent burying in snow.

MODEL(

)

Btu/h

MODEL(

)

Btu/h

AA

BB

CC

DD

EE

FF

HH

6

24K

24K

30K/36K/42K

30K/36K/42K

48K/55K

48K/55K

12K/18K

12K/18K

945

945

810

810

938

938

845

845

640

640

549

549

634

634

560

560

405

405

325

325

404

404

335

335

448

448

350

350

448

448

360

360

385

385

305

305

368

368

312

312

395

395

310

310

392

392

320

320

810

810

558

558

1369

1369

700

700

Unit:mm

Unit:mm

A

B

F

E C D

H

8

kaisai.com

Содержание 12K

Страница 1: ...PE INSTALLATION MANUAL Ceiling And Floor Type Thank you verymuch for purchasingour air conditioner Before using yourair conditioner please read thismanual carefully andkeep it forfuture reference INST...

Страница 2: ...If used as MULTI unit please refer to the Installation operation manuals packed with outdoor unit...

Страница 3: ...and firm location which is able to withstand the set s weight If the strength is not enough or installation is not properly done the set will drop to cause injury The appliance shall not be installed...

Страница 4: ...es a distance of 1 meter may not be sufficient enough to eliminate the noise The appliance is not intended for use by young children or infirm persons without supervision Don t install the air conditi...

Страница 5: ...some models 1 on some models 1 1 2 on some models 2 on some models 6 Remote controller 7 Frame 8 Mounting screw ST2 9 0 C H 9 Alkaline dry batteries Am4 10 Remote controllermanual 11 Wirecontroller 12...

Страница 6: ...eets the following requirements 1 INDOOR UNIT INSTALLATION All the pictures in this manual arefor explanation purpose only There may be slightly different fromthe air conditioner you purchased depend...

Страница 7: ...squaretimber traversely over the roof beam then install thehanging screw bolts Inlaying or embeddingthe screw bolts Use embedding screwbold crock andstick harness Timber over thebeam Roof beam Ceilin...

Страница 8: ...may shorten the life of the air conditioner 9 Since drain flows out of the outdoor unit do not place under the unit anything which must be kept away from moisture Cannot be installed hanging from ceil...

Страница 9: ...atterns the wall height on the outlet side should be 1200mm or less 1 Installing outdoor unit 2 Drain work If drain work is necessary follow the procedures below Use drain plug for drainage If the dra...

Страница 10: ...il Precautions 3 1 Flaring the pipe end 1 Cut the pipe end with a pipe cutter 2 Remove burrs with the cut surface facing downward so that the chips do not enter the pipe 5 Check that the flaring is pr...

Страница 11: ...the check is complete wipe all soapy water off 7 Disconnect charging hose from gas stop valve s service port then fully open liquid and gas stop valves Do not attempt to turn valve rod byond its stop...

Страница 12: ...tion Gas pipe Keep piping as short as possible and slope it downwards at a gradient of at least 1 100 so that air may not remain trapped inside the pipe Keep pipe size equal to or greater than that of...

Страница 13: ...it body to wire the outdoor unit indoor units and the remote controller 11 The specification of power Minimum norminal cross sectional area of conductors Rated current of appliance A Nominal cross sec...

Страница 14: ...m according to the figure 1 When attaching the control box lid make sure not to pinch any wires After all wiring connections are done fill in any gaps in the casing wiring holes with putty or insulati...

Страница 15: ...ndensed of by the air conditioner have influenced your neighborhood Whether any of the refrigerant is leaked A protection feature prevents the air conditioner from being activated for approximately 3...

Страница 16: ...for product improvement Consult with the sales agency or manufacturer for details QSDLI 016AEN CE 16122500000090 20150122 t to change without prior notice for product ncy or manufacturer for details 1...

Отзывы: