34
Visual Feedback Message Definitions
Condition
Parameters
Green LED
Red LED
Duration
Valid pushbutton pressed
ON
OFF
1/10 sec
Timeout expired
OFF
ON
1 sec
Valid access
ON
OFF
1 sec
code keyed
Access granted
ON
OFF
1/10 sec
Access granted
ON
ON
1/10 sec
(battery low condition)
Access denied
OFF
ON
1 sec
Valid programming entry
ON
OFF
1 sec
Invalid programming
OFF
ON
1 sec
entry (including
duplicate access code)
Tamper shutdown beginning
OFF
ON
2 sec
Tamper shutdown state
OFF
ON
1 sec
Tamper shutdown ending
ON
OFF
2 sec
Communication starting
ON
OFF
1 sec
Communication ending
ON
OFF
1 sec
Communication aborted
OFF
ON
1 sec
Communication in progress
ON
ON
1/10 sec
(Alternate)
(Alternate)
Hard Reset sequence in
ON
ON
1/2 sec
progress
(Alternate)
(Alternate)
Hard Reset sequence
ON
OFF
2 sec
successfully
Hard Reset sequence failed
OFF
ON
2 sec
Rate
Once
Once
Once
1 sec
1 sec
Once
Once
Once
Once
10 sec
Once
Once
Once
Once
1 sec
Continuously
ONCE
ONCE