6
2. The general procedure for all programming functions is as follows:
a. Put the lock in Programming Mode by pressing # Master Code #
b. Use the Summary of Commands Table in the appendix section of this
guide to enter the three digit command sequence (Command Type +
Function Code), followed by #.
c.
Enter the appropriate numbers as required.
d. Press # to end Programming Mode.
e.
Once the lock is in programming mode, multiple command sequences
can be entered without having to repeat the #mastercode#.
However, if there is no activity for 15 seconds at the keypad, the lock
will automatically exit from programming mode.
For example
• If the Master or Manager enters his code of
87654321
, the door will
open.
• If he enters
#87654321#
, the lock will enter into the Programming
Mode and wait for the next part of the command.
• If he enters the # sign twice at the end of the code, for example
#87654321##
, the lock will go out of Programming Mode and
return to its normal mode.
Note:
The # pound sign acts like the Enter key on a keyboard in your
communications with the lock. The # tells the lock that one part of the
entry is finished. The # serves another purpose - to distinguish a program-
ming type command from a simple Access Code to open the door. A Master
or Manager User can use the same number to open the door or to put the
lock in Programming Mode, the only difference being that he uses the #
sign in front to signal that he is about to enter a programming command.
For increased security, it is recommended that the master user code not
be used for everyday access. This can be accomplished by creating an
access user code for the master user.
Reset Procedures
There are three different “Reset” levels available in the E-Plex Lock.
Code 099#
will reset the lock to the factory default settings except for the
access code length (Master, Manager Access User codes and Time / Date
are retained if already programmed)
Code 299#
will delete all access and service user codes (Master, Manager
and M-Unit * users are retained)
Hard Reset
will return the lock to factory mode including deleting all codes,
putting the lock back to factory default values (4 digit access code length)
and making the master code 1-2-3-4-5-6-7-8. A hard reset is performed as fol-
lows.
Insert key, turn and hold in open position (Latch retracted).
Within 5 seconds, press # and then release latch
While red / green light flashes, press 1-2-3-4-5-6-7-8-# on keypad
Содержание E-PLEX 50XX SERIES
Страница 1: ...OPERATIONS MANUAL E PLEX 50XX 30XX SERIES...
Страница 19: ...Notes Notes 19...
Страница 20: ...20 Notes...
Страница 21: ...21 Notes...