States of the Lock

Factory Mode

The factory mode is one of three primary states of the E-Plex Lock. The main

characteristics of this state are:

• The E-Plex Lock opens only when the 8-digit master

combination (1-2-3-4-5-6-7-8) is keyed in.

• The visual indication for ‘access granted’ is green LED flashing once.

A high-pitched tone is also generated while the green LED is on.

• The Master User must change the combination to be able to exit the

factory mode, and switch to the access mode.

Access Mode

This mode refers to a lock that is operational for user access, and not in facto-

ry or Programming Mode.

Pushbutton Programming Mode

The E-Plex lock enters the Pushbutton Programming Mode when the user

enters the master combination or one of the manager combinations, preceded

and followed by the character ‘#’ (ex: #12345678#). Once the E-Plex Lock is in

the Pushbutton Programming Mode, the Master/Manager can enter one or more

command sequences. Each command sequence ends with a ‘#’ character that

acts like an <

enter

> character. At the very end of all sequences of program-

ming commands, enter one more # to remove the lock from the Pushbutton

Programming Mode to return to normal access mode.

Sequence of Operations for Start-Up Programming

What is the recommended sequence of operations?

With the E-Plex Lock in the factory mode.

• Program the Access Code Length (default length is four digits).

The access

code field length can only be changed when the lock is not activated

(when still in the factory mode).

• Change factory Master to your own Master Code (always eight digits) to

place lock in access mode.

Put lock in Pushbutton Programming Mode.

• Set the Date / Time

• Program the Lock ID and Unlock time

• Program the Lock for the Duration of Passage Mode (if desired)

• Program the Lock for Tamper Time Settings

• Program the Lock for Buzzer Volume

• Add Access Codes as desired

Содержание E-PLEX 50XX SERIES

Страница 1: ...OPERATIONS MANUAL E PLEX 50XX 30XX SERIES...

Страница 2: ...Passage Mode Period Procedure 6 Program the Lock for Tamper 10 Time Parameters Procedure 7 Programming the Lock for Keypad 11 Buzzer Volume Users General Information 11 User Levels 12 User Codes 13 U...

Страница 3: ...ushbutton Programming Commands 31 Visual Feedback Message Definitions 34 User List Table 35 TABLE OF CONTENTS continued A publication of Kaba Access Control 2941 Indiana Avenue Winston Salem NC 27105...

Страница 4: ...e E Plex Lock is in the Pushbutton Programming Mode the Master Manager can enter one or more command sequences Each command sequence ends with a character that acts like an enter character At the very...

Страница 5: ...r shutdown time 30 seconds Tamper attempt count 4 attempts Access code length 4 digits Latch Holdback Mode Disabled E 30xx only Swingbolt Privilege Disabled E 30xx only Privacy Privilege Disabled E 50...

Страница 6: ...finished The serves another purpose to distinguish a program ming type command from a simple Access Code to open the door A Master or Manager User can use the same number to open the door or to put th...

Страница 7: ...he E Plex Lock programmable pushbutton lock it must first be placed in Programming Mode Important This is the only programmable function that can be done during the factory mode using the factory mast...

Страница 8: ...me the software package will make the adjustment for Daylight Savings Time These must be regularly updated according to your maintenance schedule Enter 001 for date settings and 002 for time settings...

Страница 9: ...Example of Complete Entry 004 10 9 Enter another to indicate the end of programming 10 You have now programmed the lock ID 1234 and for example an Unlock Time of 10 seconds for the door PROCEDURE 5 PR...

Страница 10: ...ck see visual message chart in rear section After that it will go into a Tamper Shutdown Mode and remain locked until the end of the Tamper Shutdown Time period the length of that period is configured...

Страница 11: ...ing the Access Code without signs Put the lock into Pushbutton Programming Mode by entering before and after their Access Code 2 Each user Manager User Service User or Access User occupies one of the...

Страница 12: ...configurable period of time This period of time starts on the first use of the code Each Service User combina tion is automatically deleted from the locks memory after its period of time expires The n...

Страница 13: ...need access to the lock delete the User Code by deleting the corresponding user ID location This permits you to use the deleted user ID location for a new user If you only de activate the old code you...

Страница 14: ...r with a Manager Access Code If you change the Access Code for an existing Manager the procedure is the same Required User Level Master 1 Put the lock into Pushbutton Programming Mode 2 Enter command...

Страница 15: ...ccess Code of 00 you can only enter the door once If the door shuts upon exiting you will not be able to re enter This type of access is called a one shot code 7 Example of Complete Entry 102 025 2240...

Страница 16: ...lock is used with a wall bumper the warranty is null and void If a doorstop is required we recommend the use of a floor secured stop The environment and conditions of use determine the life of finishe...

Страница 17: ...CONTROL 2941 INDIANA AVENUE WINSTON SALEM NC 27199 3770 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST CLASS MAIL PERMIT NO 1563 POSTAGE WILL BE PAID BY ADDRESSEE WINST...

Страница 18: ...Exercise Room This lock is New Installation Replacing a conventional keyed lock Replacing a Kaba Mechanical Pushbutton Lock Replacing a Kaba Electronic Access Control Replacing a Keyless Lock other t...

Страница 19: ...Notes Notes 19...

Страница 20: ...20 Notes...

Страница 21: ...21 Notes...

Страница 22: ...Service User Access Code is automatically deleted from the lock at the end of its specified length of time However use this procedure if you want to delete the code earlier than the specified expiry t...

Страница 23: ...o Pushbutton Programming Mode 2 Enter Command 300 to activate a User Code 3 Enter the ID location NNN where NNN is the specific User ID location 023 for example 4 Example of complete entry 300 023 5 E...

Страница 24: ...that are temporarily inactive Required User Level Master Manager 1 Put the lock into Pushbutton Programming Mode 2 Enter Command 398 3 Example of Complete Entry 398 4 Enter another to indicate the end...

Страница 25: ...1 Put the lock into Pushbutton Programming Mode 2 Enter Command 400 to de activate User Access Codes 3 Enter the code 400 NNN where NNN is the specific User ID location 023 for example 4 Example of co...

Страница 26: ...ive excluding Master Manager and M Unit Codes Required User Level Master Manager 1 Put the lock into Pushbutton Programming Mode 2 Enter Command 498 to de activate all Access and Service Codes 3 Examp...

Страница 27: ...the end of the code there could be a problem with the pushbutton electronics 8 Try the Diagnostic Code again 500 1234567890 to be sure you entered all the numbers correctly and in the correct order 9...

Страница 28: ...led Required User Level Master Manager 1 Put the lock into Pushbutton Programming Mode 2 If it was disabled enter the command 014 to Enable Disable the Latch Holdback mode followed by 1 to Enable this...

Страница 29: ...will behave as though it is in a latch holdback mode since the swingbolt is completely retracted and stays retracted thus allowing free access without any codes You perform the same sequence of opera...

Страница 30: ...the thumbturn on the lock front housing clockwise and hold The swingbolt will revert back up to its locked horizontal home position Let go off the thumbturn so that it will also revert back to its nor...

Страница 31: ...p TT 02 to 20 seconds Passage Mode Timeout setup TT 01 to 24 hours duration time in hours 00 no time limit Tamper time setup TT 00 to 90 seconds Tamper wrong try setup TT 03 to 09 Buzzer volume contro...

Страница 32: ...ation 001 to 299 Combination length can be 4 to 8 digits depending on access length LL setting Add Modify Service User Access Code NNN specific User ID location 001 to 299 HH 01 to 24 hours duration t...

Страница 33: ...User Activate De Activate Passage Mode P 0 or 1 0 disable Passage Mode 1 enable Passage Mode De Activate User Access Code NNN specific User ID location 001 to 299 De Activate Manager Access Code NNN...

Страница 34: ...entry including duplicate access code Tamper shutdown beginning OFF ON 2 sec Tamper shutdown state OFF ON 1 sec Tamper shutdown ending ON OFF 2 sec Communication starting ON OFF 1 sec Communication en...

Страница 35: ...010 011 012 013 299 Access Code User Name User Type Optional Easy To Use software called E Plex Standard is also available for this product to program and maintain doors and users For more informatio...

Страница 36: ...Kaba Access Control 2941 Indiana Avenue Winston Salem NC 27105 USA Tel 800 849 8324 336 725 1331 Fax 800 346 9640 336 725 3269 www kabaaccess com www e plexlock com PKG3219 0408...

Отзывы: