26
PROCEDURE 15 - DE-ACTIVATE SERVICE USER
ACCESS CODES
A Service User Access Code should be de-activated for a certain time period -
during a Service User’s absence, for example.
Required User Level: Master, Manager
1. Put the lock into Pushbutton Programming Mode.
2. Enter Command
402#
to de-activate a Service User Access Code.
3. Enter the code
402#NNN#
, where
NNN
is the specific Manager ID
location,
024
for example.
4. Example of Complete Entry:
402#025#
.
5. Enter another
#
to indicate the end of programming.
6. You have now de-activated a Service User Access Code.
PROCEDURE 16 - DE-ACTIVATE ALL ACCESS CODES
EXCEPT MASTER, MANAGER, M-UNIT
You may need to de-activate all users, for example, during a plant shutdown.
This procedure will de-activate all regular User Access and Service Codes that
are active, excluding Master, Manager, and M-Unit Codes.
Required User Level: Master, Manager
1. Put the lock into Pushbutton Programming Mode.
2. Enter Command
498#
to de-activate all Access and Service Codes.
3. Example of Complete Entry:
498#
.
4. Enter another
#
to indicate the end of programming.
5. You have now de-activated all regular User Access Codes.
PROCEDURE 17 - ACTIVATE/DE-ACTIVATE LOCKOUT
MODE
You may need to use a global Lockout Mode, for example, during a Strike or fire
when you do not want anyone to return to work. This procedure will de-activate
all regular User Access Codes that are active, including Manager Codes, but
excluding the Master Code.
Required User Level: Master
1. Put the lock into Pushbutton Programming Mode.
2. Enter Command
499#
for Lockout Users Mode (except Master).
3. Enter
1#
to activate Lockout Mode and
0#
to de-activate.
4. Example of Complete Entry:
499#1# or 499#0#
.
5. Enter another
#
to indicate the end of programming.
6. You have now activated or de-activated Global Lockout Mode.
Содержание E-PLEX 50XX SERIES
Страница 1: ...OPERATIONS MANUAL E PLEX 50XX 30XX SERIES...
Страница 19: ...Notes Notes 19...
Страница 20: ...20 Notes...
Страница 21: ...21 Notes...