background image

9

PROCEDURE 4 - PROGRAM THE LOCK ID AND

UNLOCK TIME

Assign an ID number to each lock for configuration and auditing purposes. This is

an internal number (default 0000), and is the same as the door number. Unlock

time is the length of time the door will remain unlocked when a correct code is

entered before automatically re-locking itself.

Required User Level: Lock ID: Master, Unlock Time: Master, Manager

1. Put the lock into Pushbutton Programming Mode.

2. To set up the Lock ID, enter command

003#

.

3.

Enter NNNN

(where

NNNN

is the lock ID - a number from

0000 to

9999

). For example,

1234

.

4. Example of Complete Entry:

003#1234#

.

5. The lock ID is now in its memory.

6. Enter another

#

to indicate the end of programming, or remain in

programming mode to continue.

7. To establish Unlock Time, enter the following code:

004#TT#

,

where TT

is the time in seconds, (

TT

=02 to 20 seconds, for example 10 seconds).

8. Example of Complete Entry:

004#10#

.

9. Enter another

#

to indicate the end of programming.

10. You have now programmed the lock ID 1234 and, for example, an Unlock

Time of 10 seconds for the door.

PROCEDURE 5 - PROGRAM THE DURATION OF THE

PASSAGE MODE PERIOD

You might want to program locks for public areas, such as cafeterias, to have

free access (Passage Mode) during certain periods of the day, and revert to

required code access outside of these regular hours.

The length of time that the lock remains in Passage Mode is programmable.

The factory default length of time for Passage Mode is 9 hours - you may leave

the default, but by default, the lock’s passage mode is de-activated.

When the lock is activated at the lock keypad to go into Passage Mode, it will

automatically relock after the designated duration.

Required User Level: Master, Manager

1. Put the lock into Pushbutton Programming Mode.

2. Enter command code

005#

.

3. Then

TT#

, where

TT= 01 to 24

hours.

4. A TT entry of 00 means there is no time limit - the door remains

unlocked (permanently).

5. Enter

005 #TT#

; for example,

005#06#

for six hours.

Содержание E-PLEX 50XX SERIES

Страница 1: ...OPERATIONS MANUAL E PLEX 50XX 30XX SERIES...

Страница 2: ...Passage Mode Period Procedure 6 Program the Lock for Tamper 10 Time Parameters Procedure 7 Programming the Lock for Keypad 11 Buzzer Volume Users General Information 11 User Levels 12 User Codes 13 U...

Страница 3: ...ushbutton Programming Commands 31 Visual Feedback Message Definitions 34 User List Table 35 TABLE OF CONTENTS continued A publication of Kaba Access Control 2941 Indiana Avenue Winston Salem NC 27105...

Страница 4: ...e E Plex Lock is in the Pushbutton Programming Mode the Master Manager can enter one or more command sequences Each command sequence ends with a character that acts like an enter character At the very...

Страница 5: ...r shutdown time 30 seconds Tamper attempt count 4 attempts Access code length 4 digits Latch Holdback Mode Disabled E 30xx only Swingbolt Privilege Disabled E 30xx only Privacy Privilege Disabled E 50...

Страница 6: ...finished The serves another purpose to distinguish a program ming type command from a simple Access Code to open the door A Master or Manager User can use the same number to open the door or to put th...

Страница 7: ...he E Plex Lock programmable pushbutton lock it must first be placed in Programming Mode Important This is the only programmable function that can be done during the factory mode using the factory mast...

Страница 8: ...me the software package will make the adjustment for Daylight Savings Time These must be regularly updated according to your maintenance schedule Enter 001 for date settings and 002 for time settings...

Страница 9: ...Example of Complete Entry 004 10 9 Enter another to indicate the end of programming 10 You have now programmed the lock ID 1234 and for example an Unlock Time of 10 seconds for the door PROCEDURE 5 PR...

Страница 10: ...ck see visual message chart in rear section After that it will go into a Tamper Shutdown Mode and remain locked until the end of the Tamper Shutdown Time period the length of that period is configured...

Страница 11: ...ing the Access Code without signs Put the lock into Pushbutton Programming Mode by entering before and after their Access Code 2 Each user Manager User Service User or Access User occupies one of the...

Страница 12: ...configurable period of time This period of time starts on the first use of the code Each Service User combina tion is automatically deleted from the locks memory after its period of time expires The n...

Страница 13: ...need access to the lock delete the User Code by deleting the corresponding user ID location This permits you to use the deleted user ID location for a new user If you only de activate the old code you...

Страница 14: ...r with a Manager Access Code If you change the Access Code for an existing Manager the procedure is the same Required User Level Master 1 Put the lock into Pushbutton Programming Mode 2 Enter command...

Страница 15: ...ccess Code of 00 you can only enter the door once If the door shuts upon exiting you will not be able to re enter This type of access is called a one shot code 7 Example of Complete Entry 102 025 2240...

Страница 16: ...lock is used with a wall bumper the warranty is null and void If a doorstop is required we recommend the use of a floor secured stop The environment and conditions of use determine the life of finishe...

Страница 17: ...CONTROL 2941 INDIANA AVENUE WINSTON SALEM NC 27199 3770 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST CLASS MAIL PERMIT NO 1563 POSTAGE WILL BE PAID BY ADDRESSEE WINST...

Страница 18: ...Exercise Room This lock is New Installation Replacing a conventional keyed lock Replacing a Kaba Mechanical Pushbutton Lock Replacing a Kaba Electronic Access Control Replacing a Keyless Lock other t...

Страница 19: ...Notes Notes 19...

Страница 20: ...20 Notes...

Страница 21: ...21 Notes...

Страница 22: ...Service User Access Code is automatically deleted from the lock at the end of its specified length of time However use this procedure if you want to delete the code earlier than the specified expiry t...

Страница 23: ...o Pushbutton Programming Mode 2 Enter Command 300 to activate a User Code 3 Enter the ID location NNN where NNN is the specific User ID location 023 for example 4 Example of complete entry 300 023 5 E...

Страница 24: ...that are temporarily inactive Required User Level Master Manager 1 Put the lock into Pushbutton Programming Mode 2 Enter Command 398 3 Example of Complete Entry 398 4 Enter another to indicate the end...

Страница 25: ...1 Put the lock into Pushbutton Programming Mode 2 Enter Command 400 to de activate User Access Codes 3 Enter the code 400 NNN where NNN is the specific User ID location 023 for example 4 Example of co...

Страница 26: ...ive excluding Master Manager and M Unit Codes Required User Level Master Manager 1 Put the lock into Pushbutton Programming Mode 2 Enter Command 498 to de activate all Access and Service Codes 3 Examp...

Страница 27: ...the end of the code there could be a problem with the pushbutton electronics 8 Try the Diagnostic Code again 500 1234567890 to be sure you entered all the numbers correctly and in the correct order 9...

Страница 28: ...led Required User Level Master Manager 1 Put the lock into Pushbutton Programming Mode 2 If it was disabled enter the command 014 to Enable Disable the Latch Holdback mode followed by 1 to Enable this...

Страница 29: ...will behave as though it is in a latch holdback mode since the swingbolt is completely retracted and stays retracted thus allowing free access without any codes You perform the same sequence of opera...

Страница 30: ...the thumbturn on the lock front housing clockwise and hold The swingbolt will revert back up to its locked horizontal home position Let go off the thumbturn so that it will also revert back to its nor...

Страница 31: ...p TT 02 to 20 seconds Passage Mode Timeout setup TT 01 to 24 hours duration time in hours 00 no time limit Tamper time setup TT 00 to 90 seconds Tamper wrong try setup TT 03 to 09 Buzzer volume contro...

Страница 32: ...ation 001 to 299 Combination length can be 4 to 8 digits depending on access length LL setting Add Modify Service User Access Code NNN specific User ID location 001 to 299 HH 01 to 24 hours duration t...

Страница 33: ...User Activate De Activate Passage Mode P 0 or 1 0 disable Passage Mode 1 enable Passage Mode De Activate User Access Code NNN specific User ID location 001 to 299 De Activate Manager Access Code NNN...

Страница 34: ...entry including duplicate access code Tamper shutdown beginning OFF ON 2 sec Tamper shutdown state OFF ON 1 sec Tamper shutdown ending ON OFF 2 sec Communication starting ON OFF 1 sec Communication en...

Страница 35: ...010 011 012 013 299 Access Code User Name User Type Optional Easy To Use software called E Plex Standard is also available for this product to program and maintain doors and users For more informatio...

Страница 36: ...Kaba Access Control 2941 Indiana Avenue Winston Salem NC 27105 USA Tel 800 849 8324 336 725 1331 Fax 800 346 9640 336 725 3269 www kabaaccess com www e plexlock com PKG3219 0408...

Отзывы: