background image

V.1.0 16.05.2011 

 

 

 

 

 

 

 

 

T

T

i

i

m

m

e

e

 

 

D

D

e

e

l

l

a

a

y

y

 

 

S

S

e

e

t

t

t

t

i

i

n

n

g

g

:

:

 

 

0

0

/

/

3

3

/

/

6

6

/

/

1

1

0

0

 

 

S

S

e

e

c

c

.

.

 

 

 

A Setting: 

 

Case 1- 

 
 
 

 

Case 2- 

 
Case 3- 
 
 

 
Case 4-

 

 

Case 5- 
 
 

 
Case 6- 
 

Power on the DB1260-PTO when door is close:

 Bolt will not retract if time delay setting is 0 second; Bolt 

will retract if time delay setting is 3/6/10 seconds, then after a time delay (3/6/10 sec), bolt will automatically 
extend. However, in these time delay periods, if door is opened and then closed again, bolt will extend right 
away. 

 

Power on the DB1260-PTO when door is open:

 Bolt will retract, and extend right away if door is closed. 

 

Power on the DB1260-PTL when door is close:

  After a time delay (0/3/6/10 sec), bolt will automatically 

extend. However, in these time delay periods, if door is opened and then closed again, bolt will extend right 
away. 

 

Power on the DB1260-PTL when door is open:

 Bolt will extend right away if door is closed. 

 

Push the exit-switch when DB1260 is powered and bolt extends:

 Bolt will retract, and after a time delay 

(3/6/10 sec), bolt will automatically extend. However, in these time delay periods, if door is opened and then 
closed again, bolt will extend right away. 

 

Push the exit-switch when DB1260 is powered and door is open:

  Bolt will extend right away if door is 

closed. 

 

B Setting: 

 

Case 1- 
 
 
 

 
Case 2- 
 
 

 
Case 3- 
 
 

 
Case 4- 
 
 

 
Case 5- 
 
 

 
Case 6- 

 

 

Power on the DB1260-PTO when door is close:

 Bolt will not retract if time delay setting is 0 second; Bolt 

will retract if time delay setting is 3/6/10 seconds, then after a time delay (3/6/10 sec), bolt will automatically 
extend. However, in these time delay periods, if door is opened and then closed again, the time delay will 
reset and count again. 

 

Power on the DB1260-PTO when door is open:

  Bolt will retract. If door is closed, after a time delay 

(0/3/6/10 sec), bolt will automatically extend. However, in these time delay periods, if door is opened and then 
closed again, the time delay will reset and count again. 

 

Power on the DB1260-PTL when door is close:

  After a time delay (0/3/6/10 sec), bolt will automatically 

extend. However, in these time delay periods, if door is opened and then closed again, the time delay will 
reset and count again. 

 

Power on the DB1260-PTL when door is open:

 if door is closed, after a time delay (0/3/6/10 sec), bolt will 

automatically extend. However, in these time delay periods, if door is opened and then closed again, the time 
delay will reset and count again. 

 

Push the exit-switch when DB1260 is powered and bolt extends:

 Bolt will retract, and after a time delay 

(3/6/10 sec), bolt will automatically extend. However, in these time delay periods, if door is opened and then 
closed again, the time delay will reset and count again. 

 

Push the exit-switch when DB1260 is powered and door is open:

  if door is closed, after a time delay 

(0/3/6/10 sec), bolt will automatically extend. However, in these time delay periods, if door is opened and then 
closed again, the time delay will reset and count again. 

 

If bolt is out and not in the right position, after 6 seconds, bolt will automatically retract. Later, bolt will extend right away if 
door is opened and then closed again. 

 

If bolt is out and not in the right position, in 6 seconds, bolt will automatically retract if door is opened. Later, bolt will extend 
right away if door is closed again. 

 
Note:  

1. When power is on and door is close, system will automatically set 3 seconds time delay once the exit-switch is

 

pushed to close momentarily and if the 

Time Delay Setting

 is set to 0 second. 

 

 

2. The bolt will retract when the exit-switch (

Brown

 Wire & 

Yellow

 Wire) is pushed to close momentarily. 

 

 

The bolt will remain retract ( For example: during business hours) as long as these two wires are closed. 

 

B

B

i

i

-

-

c

c

o

o

l

l

o

o

r

r

 

 

L

L

E

E

D

D

 

 

S

S

t

t

a

a

t

t

u

u

s

s

 

 

(

(

E

E

 

 

O

O

p

p

t

t

i

i

o

o

n

n

)

)

:

B

B

u

u

z

z

z

z

e

e

r

r

 

 

S

S

t

t

a

a

t

t

u

u

s

s

 

 

(

(

T

T

 

 

O

O

p

p

t

t

i

i

o

o

n

n

)

)

:

:

 

 

1. Extend Successfully: 

Green blinks every 5 seconds. 

1. Extend Successfully: 

Beep! Beep!. 

2. Wait for Extend: 

Red blinks fast. 

2. Extend Fail: 

Beep! … Beep! 10 seconds. 

3. Delay Period: 

Red blinks slowly. 

3. Retract Successfully:  Beep!. 

4. Wait for Delay Start: 

Red on. (B Setting only) 

Note: Set DIP4 ON/OFF to set Buzzer ON/OFF. 

5. Bolt Remain Retract: 

Red/Green blinks alternatively. 

DB1260 Series

 

Отзывы: