Manual
Maintenance
B-eco
04043988 - 02/2014
63
8.2
Replacing the UPS batteries
To ensure the function of the uninterruptible power supply, the UPS batteries must
be replaced with new batteries every 3 years.
A set of replacement batteries consisting of 6 batteries can be purchased from Kaba
under the order number 04043851.
Specification NiMH battery, 1.2 V, capacity min. 2000 mAh, size AA
NOTICE
Wrong battery types or incorrectly inserted batteries can overheat and damage the
device.
•
Use new identical batteries conforming to the above specification only.
•
Do not use any primary battery cells.
•
Ensure correct polarity.
•
Remove the TORX8 screw (arrow).
•
Remove the cover of the battery compartment.
•
Remove old batteries.
•
Press new batteries into the holding clamps.
• Re-attach
cover.
After an operating time of about 10 hours, the batteries are completely charged,
and the UPS is ready for use.
Old batteries must be disposed of according to state and local regulations.