6.3
1-click installation
In combination with the B-COMM communication software, the terminal can be put
into operation almost automatically.
System requirements
•
B-COMM communication software version 3.7 and higher.
Required settings (activated by default when delivered)
•
Network configuration via DHCP.
•
DNS configuration via DHCP.
•
Check box "Enable host registration" ticked.
The device is preset in the factory for 1-click installation.
6.3.1
Start-up procedure
•
Plug in network cable and supply device with power.
•
After booting, the device cyclically reports to the B-COMMs active in the
network.
At this point, the following display is shown until start-up by a B-COMM is
complete:
B-eco
Serial number: <Serial
number>
IP address: <IP address>
Waiting for registration
•
After the device is found by B-COMM, the relevant data that identify the
device are queried.
•
If the device is not known, it is entered in B-COMM under the
B-COMM
Terminal Discovery
client under the
BCTDS
(Terminal Discovery Stream)
stream.
•
If the device is to be managed using B-COMM, it can be moved to the desired
stream, and the communication parameters can be set.
•
After having assigned the device firmly to B-COMM, B-COMM first updates the
settings of the device and then makes a backup copy together with the
"sop.ini" license file.
•
After loading the specific parameters and master records from the host, the
device is automatically restarted and is then ready for operation.
•
The device now informs the B-COMMs active in the network that registration
is complete. Other B-COMMs then remove the device again from the
BCTDS
stream.