Fine adjust the focus
①
Press and hold the [
J
] button.
v
Focus adjust mode will be activated and “FOCUS ADJUST MODE”
is displayed on the monitor screen.
v
The contours are emphasized as the iris opens and the depth of
field becomes shallow.
v
After adjustment, press [
K
,
H
,
I
] / [SET]/[MENU] to exit focus
adjust mode. The mode is also automatically deactivated after
about 30 seconds.
Memo
v
During the focus adjust mode, the electronic shutter will
function automatically. As a result the screen will
appear grainy. This is not a malfunction.
②
Shoot the subject.
③
Confirm that the catch is at position A in the diagram, and then
rotate the knob to adjust the focus to the optimum position.
④
Rotate the gear for focus adjustment knob approximately one gear
tooth in the direction of the arrow in the diagram to correct the
focus shift when mounting the dome cover.
⑤
Peel off the protection sheet temporarily and cover the dome cover
to check the focus. After checking, paste the protection sheet back
on the dome cover.
.
A
Gear tooth
Knob
Catch
<IR LED removed>
<Continued on the following page>
Adjustment
E-37