NX-MD1R/NX-MD1
1-35
(4) Adjustment of the disk
YES
NO
YES
NO
NG Judgment Code Table
Code
NG item in adjustment
Insert the
premastered disk.
Reading of TOC ends.
FL indication
ON TUNING
Automatic adjustment starts.
Adjustment OK?
FL indication
OK TUNING
FL indication
NG ERR: xXX!
XX: Refer to the NG judgment code table.
Insert a recordable
disk.
FL indication
ON TUNING
FL indication
ON TUNING
Automatic adjustment starts.
Adjustment OK?
FL indication
NG ERR: xXX!
Refer to the NG judgment code table.
Automatic adjustment
ends.
Press the STANDBY/ON key on the
main unit or remote controller.
Cut off the power supply after
cancelling the TEST MODE.
00
Automatic adjustment is incomplete.
01
Rest switch detection
02
Focus-on
03
EF balance, tracking offset adjustment (Pit area)
04
ABCD level (I-V resistance) adjustment (Pit area)
05
Focus servo AGC (Pit area)
06
Tracking servo AGC (Pit area)
07
Focus bias adjustment (Pit area)
08
EF balance, tracking offset adjustment (GRV area)
09
ABCD level (I-V resistance) adjustment (GRV area)
0A
Focus servo AGC (GRV area)
0B
Tracking servo AGC (GRV area)
0C
Focus bias adjustment (GRV area)
0D
Room temperature measurement
0E
Write in EEPROM
FF
Automatic adjustment is complete.
Press the MD EJECT
key on the main unit.
Press the MD PLAY
key on the
remote controller.
Press the STOP key
on the remote controller.
Press the MD PLAY
key on the
remote controller.
Press the STOP key
on the remote controller.
Press the MD EJECT
key on the main unit.