NX-MD1R/NX-MD1
1-34
2) MD section
(1) Setup of the TEST MODE 1
FL indication
MD TEST MODE 1
Setup is complete.
(2) Initialization of the EEPROM
(The EEPROM can be initialized on the precondition that the
setup of the TEST MODE 1 is complete. After setup of the
TEST MODE 1, proceed to the following operations with the
remote controller*.)
* For EJECT operation, use the EJECT key on the main unit.
Initialization of the EEPROM
Press the REC SPEED key
on the remote controller.
FL indication
DATA INITI.
Setup is complete.
(3) Adjustment of the playback laser power
Insert the laser power
meter sensor.
Press the "2" key on
the remote controller.
Set up the playback
laser power.
Adjust the power to be 0.68 mW or
more. If the value exceeds 0.68 mW,
approximate it to 0.68 mW as
accurately as possible.
MD playback laser power
adjustment is complete.
Press the "4" key on
the remote controller.
Set up the recording
laser power.
Adjust the power to be 6.23 mW or
more. If the value exceeds 6.23 mW,
approximate it to 0.68 mW as
accurately as possible.
Setup of the MD laser
power is complete.
Press the STANDBY/ON key on
the main unit
FL indication
L.POW PLAY
FL indication
L.POW REC
Decrease the laser
power with the
B.SKIP key on the
remote controller.
Press the STOP key on
the remote controller.
Increase the laser
power with the
F.SKIP key on the
remote controller.
While pressing both the STOP key
and MD PLAY key, turn on the
primary power supply.
Decrease the laser
power with the
B.SKIP key on the
remote controller.
Increase the laser
power with the
F.SKIP key on the
remote controller.
Press the STOP key on
the remote controller.
Press the MD EJECT
key on the main unit.