digital audio
modular
processing system
C8000
4/8/16 channels DSP with SDI & system-bus I/O
C8492(B)
page
11/30
RESET
Restart Module
Pressing <RESTART> performs a warm start (soft reset)
Initialize and Restore
Pressing <INITIALIZE> restores the factory default values for all
Factory Defaults
parameters of the module including all presets. You will lose
your presets and settings. It's highly recommended to backup the
settings and presets to a PC first.
BACKUP / RESTORE
Backup Settings and
Pressing <BACKUP> will put all active parameters and the
Presets to File
content of all presets into an XML file.
You may store such file on a PC.
Restore Settings and
You may browse a matching XML file from a PC.
Presets from File
Pressing <RESTORE> will overwrite all active parameters and the
content of the presets with the content from the backup file.
ROUTING
only available for C8492(B)
You may purchase the (B) option that expands the capabilities so the module can be used in standard
c8k applications together with other c8k modules to allow for Dolby processing, AES / MADI or even
analog break out for example. In this case the ROUTING pane will be accessible. If the (B) option is
not activated the ROUTING pane will not appear in the GUI. In this case the signal routing to and
from the DSPs is only possible via the SDI embedder / de-embeder.