– 78 –
No.
Item
Setting range
Unit
U037
Speed during soft start
The number of revolutions set with this memory switch is given precedence
even if it is lower than the lowest speed by pedal.
The initial value varies with the machine head. (0:OFF)
One needle: 170 sti/min Two needles: 200 sti/min
100 to 3500
sti/min
U038
Speed during one-shot stitching
The maximum number of revolutions during soft start differs with the machine
head.
100 to 3500
sti/min
U039
Start position of rotation
Set start position from neutral pedal position. (Pedal Stroke)
10 to 1000
-
U040
Start position of acceleration
Set accelerating position from neutral pedal position. (Pedal Stroke)
10 to 1000
-
U041
Start position of lifting of presser foot
Set work clamp lift position from neutral pedal position. (Pedal Stroke)
-500 to -10
-
U042
Start position of lowering of presser foot
Set work clamp fall position from neutral pedal position. (Pedal Stroke)
10 to 500
-
U043
Start position of thread trimming
Set thread trimming starting position from neutral pedal position. (Pedal Stroke)
-1000 to -100
-
U044
Position that maximum sewing speed is reached
Set maximum speed reaching position from neutral pedal position. (Pedal
Stroke)
10 to 15000
-
U045
Pedal neutral-position correction value
Set neutral position of pedal sensor.
-150 to 150
-
U047
Presser-foot lift finishing position
The position to which the presser foot goes up when the back part of the pedal
is depressed to its first step. (1st-step spring position)
-1000 to -100
-
U048
Function of lifting the presser foot by depressing the pedal
Whether or not the presser-foot lifting operation is carried out by depressing the
back part of pedal is set.
0: No operation / 1: Operation
0 to 1
-
U049
Presser foot lowering time
Time to lower the presser foot is set.
0 to 500
ms
U051
Correction of turning-ON of reverse feed stitching (at start)
-50 to 50
Degree
U052
Correction of turning-OFF of reverse feed stitching (at start)
-50 to 50
Degree
U053
Correction of turning-OFF of reverse feed stitching (at end)
-50 to 50
Degree
U054
Standby time until the presser foot starts going up
Time to be elapsed from the moment the pedal is depressed to the 1st step to
the moment the presser foot starts going up.
0 to 200
ms
U056
Reverse-rotation needle-up after thread trimming
The initial value differs with the machine head.
0: Reverse-rotation needle-up is not performed / 1: Reverse-rotation needle-up
is performed
0 to 1
-
Содержание SC-956
Страница 1: ...INSTRUCTION MANUAL LH 4500C Series SC 956...
Страница 180: ...175 11 GAUGE PARTS LIST 43 22 TABLE OF EXCHANGING GAUGE PARTS LH 4578C TYPE F LH 4578C F type...
Страница 181: ...176 23 TABLE OF EXCHANGING GAUGE PARTS LH 4578C 7 LH 4578C 7...
Страница 182: ...177 47 24 TABLE OF EXCHANGING GAUGE PARTS LH 4588C 7 LH 4588C 7...