– 83 –
5-6. List of errors
Error
code
Description of error
Cause
Item to be checked
E000
Execution of data initial-
ization (This is not an
error.)
・
The existing control box has been
removed and a new one is mount-
ed.
・
In the case the initialization opera-
tion is executed.
This is not a failure.
E007
Motor overload
・
In the case the machine head is
locked.
・
In the case of sewing extra-heavy
weight material that exceeds the
guaranteed material thickness.
・
In the case the motor fails to rotate.
・
In the case of the motor or driver
failure.
・
Check whether the pulley is entangled with
thread.
・
Check whether the motor output connector
(4P) has loosened.
・
Check whether the motor can be turned
smoothly by hand.
E009
Overtime of solenoid
energization
・
In the case the length of solenoid
energizing time has exceeded the
assumed one.
E011
Media is not inserted
・
In the case no media is inserted.
・
Turn the power OFF and check for a media.
E012
Read error
・
In the case data stored on the me-
dia cannot be read.
・
Turn the power OFF and check for a media.
E013
Write error
・
In the case data cannot be written
on the media.
・
Turn the power OFF and check for a media.
E014
Write protect
・
In the case the media is placed in
the write-prohibition state.
・
Turn the power OFF and check for a media.
E015
Format error
・
In the case formatting of the media
cannot be carried out.
・
Turn the power OFF and check for a media.
E016
External media over-ca-
pacity
・
In the case the capacity of media is
not enough.
・
Turn the power OFF and check for a media.
E019
File size over
・
In the case of attempting to read
the custom pitch data or conden-
sation custom data which exceeds
the maximum permissible data size
into the memory of sewing machine
from the USB thumb drive.
・
Turn the power OFF and check the USB
thumb drive.
E022
File undetected
・
In the case of attempting to read a
file which is not stored in the USB
thumb drive into the operation pan-
el.
E024
Continuous sewing time
is exceeded
E032
File compatibility error
・
In the case the file is not compati
-
ble.
・
Turn the power OFF and check for a media.
E071
Slip-off of the motor con
-
nector
・
In the case the motor connector
has slipped off.
・
Check for looseness and slip-off of the mo
-
tor output connector.
E072
Motor overload when the
thread trimmer operates
・
Same as E007.
・
Same as E007.
E079
Overload operation error
・
Load applied to the main shaft
motor is excessively large.
E204
USB insertion
・
In the case the sewing machine
is started up without removing the
USB thumb drive.
・
Remove the USB thumb drive.
Содержание SC-956
Страница 1: ...INSTRUCTION MANUAL LH 4500C Series SC 956...
Страница 180: ...175 11 GAUGE PARTS LIST 43 22 TABLE OF EXCHANGING GAUGE PARTS LH 4578C TYPE F LH 4578C F type...
Страница 181: ...176 23 TABLE OF EXCHANGING GAUGE PARTS LH 4578C 7 LH 4578C 7...
Страница 182: ...177 47 24 TABLE OF EXCHANGING GAUGE PARTS LH 4588C 7 LH 4588C 7...