– 81 –
No.
Item
Setting range
Unit
U199
Pedal giving priority to sewing machine for standing work
The switch which is given priority when the pedal is used for sewing machine
for standing work is set.
0: Start switch is given priority / 1: Start switch is not given priority
0 to 1
-
U201
Bobbin thread remaining amount at the start of thread tension correction.
0 to 100
U202
Thread correction amount at the time the bobbin thread remaining
amount is minimized.
50 to 200
U273
Start enable/disable setting when lifting the presser foot
Enable/disable of input for starting the sewing machine after lowering the
presser foot which is placed in its upper position is changed over.
0: Enable / 1: Disable
0 to 1
-
U286
Thread presser, sewing speed
This memory switch is used for setting the sewing speed when operating the
thread presser.
100 to 3000
sti/min
U288
Thread presser, ON angle
This memory switch is used for setting the angle at which the thread presser is
placed in ON at the beginning of sewing.
180 to 290
Degree
U289
Thread clamp OFF angle
The degree of an angle of the main shaft at which the thread clamp is turned
OFF at the beginning of sewing is set.
210 to 359
Degree
U290
Thread presser, AK operating time
This memory switch is used for setting the time during which the AK device is in
the ON state when the thread presser operates.
0 to 50
ms
U293
Thread presser, sewing speed resetting angle
This memory switch is used for setting the angle at which the thread presser
sewing speed is reset.
* This setting is enabled when the thread presser operates.
0 to 720
Degree
U294
Thread presser, initial suction time
The low-current time during the initial state of suction for the thread clamp.
0 to 200
ms
U295
Angle of thread floating prevention output during angular stitching
This memory switch is used for setting the angle threshold for determining of
change in needle-bar stop output at the time of angular stitching.
30 to 175
Degree
U318
Correction of reverse-feed lever operation starting position
-40 to 40
U319
Correction of position at which the operation of reverse-feed lever is
maximized
-40 to 40
U400
Panel operation mode
This memory switch is used for specifying the mode of the sewing screen that
is displayed at the time of startup.
0: Maintenance personnel mode / 1: Operator mode
0 to 1
-
U401
Input unit of stitch length
0: Stitch length (mm) / 1: Number of stitches per inch /
2: Number of stitches in 3 cm
0 to 2
-
U402
Automatic lock time
The sewing machine is automatically locked in the case the operation panel is
not operated for a predetermined period of time.
0 to 300
Second