– 24 –
(16) Adjustment of the moving knife and counter knife position
Standard adjustment
Counter knife position : The clearance between the counter knife
5
and the needle hole guide
6
is 0.5 mm.
Moving knife position : Before thread trimmer operation (standby state), the distance from the needle
plate
4
to the tip of the thread trimmer lever (small)
7
is 18.5 mm.
(17) Adjustment of the height of the moving knife and counter knife
Standard adjustment
Moving knife
8
: The amount of mesh of the needle hole guide
6
with the moving knife
8
is 0.15 mm.
Counter knife
5
: The height between the needle hole guide
6
and the blade of the counter knife
5
is 0.1
to 0.15 mm.
(Needle plate)
0.1 to 0.15 mm
Moving knife link
Содержание LK-1900AN
Страница 30: ... 18 11 Hook adjustment Standard adjustment For DP 17 For DP 5 0 05 to 0 1 mm ...
Страница 97: ... 85 3 Thread tension area 4 Thread trimmer area Grease Grease JUKI Grease A Grease JUKI Grease A JUKI Grease A ...
Страница 100: ... 88 8 Needle thread clamp mechanism area Grease Grease Grease Grease Grease ...
Страница 101: ... 89 9 LK 1901AN relations Grease Grease Grease Grease Grease Grease Grease Grease ...
Страница 102: ... 90 10 LK 1903AN relations Grease Grease Grease ...
Страница 129: ... 117 12 Circuit diagrams 1 Block diagram A ...
Страница 130: ... 118 2 Power supply circuit diagram A ...
Страница 131: ... 119 3 Power supply circuit diagram B ...
Страница 132: ... 120 4 Power supply circuit diagram C ...
Страница 133: ... 121 5 Servo motor circuit diagram ...
Страница 135: ... 123 7 MAIN PANEL board circuit diagram ...
Страница 139: ......