– 66 –
7. Miscellaneous
(1) Various printed wiring boards
1) FLT-T board
· Single-phase 100V to 120V
· 3-phase 200V to 240V
· Single-phase 200V to 240V
Pulse generation is carried out for the purposes of power supply rectification, noise reduction, and the de
-
tection of a momentary interruption.
Voltage changeover
CN1 : Power input
←
Power switch
CN2 : Power output
→
MAIN board
CN3 : Momentary interruption detection signal
→
MAIN board
・
In the signal-phase mode, the power
supply is connected to Pins 4-5.
・
In the 3-phase mode, the power
supply is connected to Pins 4-5-6.
・
Connected to 100V side for
100V to 120V.
・
Connected to 200V side for
200V to 240V.