– 69 –
4) LED3 for SDC board error check
No. of LED3
flashes
Error description
Display of op-
eration panel
Remarks
Turn on
Nil
Dimly turn on in ordinary state
1
Main shaft motor lock
E007
Failure in revolving for 2 seconds
2
Error in phase Z
E303
Failure in phase Z detection
About 1.5 turns
3
Error in phases A and B
E730
Failure in phases A and B detection
About 0.5 turns
4
Motor position sensor error E731
Logical error in U, V, W
5
IPM error
E901
Error output generation from IPM
6
Undervoltage
E813
Source voltage -20% or more
7
Motor reverse rotation
E733
Irregular motor revolutions
8
Overvoltage
E811
Source v20% or less
9
Power interruption
Display disabled Power interruption of 40 msec or more
10
Not used
11
+85V power system error
E903
SDC board fuse F1 blow-off
12
+33V power system error
E904
SDC board fuse F2 blow-off
13
Overheating
E905
Radiator panel of SDC board heated at
85℃ or more
14
Not used
15
Communication error
E916
Failure in communication with the MAIN
board
Содержание LK-1900AN
Страница 30: ... 18 11 Hook adjustment Standard adjustment For DP 17 For DP 5 0 05 to 0 1 mm ...
Страница 97: ... 85 3 Thread tension area 4 Thread trimmer area Grease Grease JUKI Grease A Grease JUKI Grease A JUKI Grease A ...
Страница 100: ... 88 8 Needle thread clamp mechanism area Grease Grease Grease Grease Grease ...
Страница 101: ... 89 9 LK 1901AN relations Grease Grease Grease Grease Grease Grease Grease Grease ...
Страница 102: ... 90 10 LK 1903AN relations Grease Grease Grease ...
Страница 129: ... 117 12 Circuit diagrams 1 Block diagram A ...
Страница 130: ... 118 2 Power supply circuit diagram A ...
Страница 131: ... 119 3 Power supply circuit diagram B ...
Страница 132: ... 120 4 Power supply circuit diagram C ...
Страница 133: ... 121 5 Servo motor circuit diagram ...
Страница 135: ... 123 7 MAIN PANEL board circuit diagram ...
Страница 139: ......