– 92 –
10. Error list
Display
Name of error
Description of error
Corrective measure
Remarks
Machine lock error
The main shaft of the sewing machine does not
rotate due to some troubles.
Turn OFF the power switch and remove the cause of
troubles.
Pattern No. error
Back-uped pattern No. has not been registered
in the data ROM, or it is set to readout inopera-
tive.
Pattern No. is set to “0”.
Press the reset switch and check the pattern No.
Check the contents of memory switch No. 201.
Needle bar UP position
error
Needle bar is not in the specified UP position.
Turn the hand pulley to return the needle bar to its
specified UP position.
Sewing area over
The sewing area is beyond the limit.
Press the reset switch and check the pattern and X/Y
scale rate.
This error is output when
max. sewing area, 30 x
40 is over. Interference of
the work clamp foot with
needle is not protected.
Enlargement error
The sewing pitch is beyond 10 mm.
Press the reset switch and check the pattern and X/Y
scale rate.
Pattern data error
The pattern data cannot be adopted.
Turn OFF the power switch and check the data ROM.
Temporary stop
Temporary stop by operating the reset switch
while the sewing machine is running. (Refer to
memory switch No. 31.)
Re-start or return-to-origin after thread trimming by
means of the reset switch (For the details, refer to the
item "
!
.-[6]-4. How to use the temporary stop".)
Machine head identifi
-
cation error
The type of machine head and the type of con-
trol box do not match.
Turn the power OFF and contact JUKI or your distribu-
tor.
Grease replenishing
time information
Information as to the time of replenishing the
designated places with grease.
Replenish the designated places with grease and set
memory switch No. 245 to “0” with the reset key. Error
can be released with the reset key when immediate
replenishing with grease cannot be performed during
sewing operation.
Refer to the item "(9)-5.
Grease-up procedures for
the specified position
".
Содержание LK-1900AN
Страница 30: ... 18 11 Hook adjustment Standard adjustment For DP 17 For DP 5 0 05 to 0 1 mm ...
Страница 97: ... 85 3 Thread tension area 4 Thread trimmer area Grease Grease JUKI Grease A Grease JUKI Grease A JUKI Grease A ...
Страница 100: ... 88 8 Needle thread clamp mechanism area Grease Grease Grease Grease Grease ...
Страница 101: ... 89 9 LK 1901AN relations Grease Grease Grease Grease Grease Grease Grease Grease ...
Страница 102: ... 90 10 LK 1903AN relations Grease Grease Grease ...
Страница 129: ... 117 12 Circuit diagrams 1 Block diagram A ...
Страница 130: ... 118 2 Power supply circuit diagram A ...
Страница 131: ... 119 3 Power supply circuit diagram B ...
Страница 132: ... 120 4 Power supply circuit diagram C ...
Страница 133: ... 121 5 Servo motor circuit diagram ...
Страница 135: ... 123 7 MAIN PANEL board circuit diagram ...
Страница 139: ......