FX-3R Maintenance
Guide
8-2
8-1-2. Adjusting the Speed Controller of the Bank-Up Cylinder
(Optional Replacement Table)
1) For the speed controllers of the right side
cylinder, adjust those of the fixed and left side
cylinders.
2)
The speed controllers have been set so that
the bank-up cylinder completes ascent
operation in 3.8 to 4.2 seconds, descent
operation in 2 to 2.5 seconds. (When
assembled)
•
UP
speed
: To be adjusted by the
upper speed controller.
Upper speed
controller
Lower speed
controller
Figure 8-1-2-1 Back-Up Cylinder
Positions
If the up speed of the left cylinder is too fast,
turn the speed controller adjustment screw
clockwise.
•
DOWN speed: To be adjusted by the lower
speed controller.
If the down speed of the left cylinder is too
fast, turn the speed controller adjustment
screw clockwise.
3)
If the up and down speeds of the left and right cylinders are the same, lock the adjustment
screws of the speed controllers with the lock screws.
4)
After the adjustment screws have been locked, recheck the up and down speeds.
8-1-3. Replacing the Bank-Up Detection Sensor
(Optional Replacement Table)
1)
Turn off the power to the main unit.
2)
Lower the lifter.
3)
Loosen the fixing screws, remove the sensor
and replace it with a new one.
4)
Reassemble the components in the reverse
order of disassembly.
<Adjustment>
1) Turn on the power to the main unit.
2) Make sure that there is a 0.9mm gap
between the bank sensor dog and sensor
as shown on the right.
Figure 8-1-3-1 Back-Up Detection Sensor
Rev. 1.00