FX-3R Maintenance Guide
3-10
3-4-3. Sticking the Label
After the label sticking surface has been degreased, stick the label. (The following Figure shows the
LF and RR heads.)
The LR and RF heads have the cable running direction opposite to that of the LF and RR heads.
Stick the label in an orientation so that it can be seen from the front.
Figure 3-4-3-1 Amplifier Replacement (Left: Label/Right: Label Stuck)
3-4-4. Adjusting the HMS Height
Move the HMS sensor to a point above the calibration block. Loosen the SEMS cap bolts
c
at two
locations and adjust the distance between the bottom surface of the height sensor and the top
surface of the calibration block to a specified value of 40
±
0.2 mm. At this time, check that both the
FAR and NEAR indicators are lit. After the distance has been adjusted to a specified level, secure
the height sensor with the SEMS cap bolts
c
at two locations.
NEAR
indicator
FAR
indicator
c
SM6032002TN
SEMS cap bolt M3
×
20
CAL block top surface
40
±
0.2mm
[HMS sensor range indicator: lighting status]
NEAR/FAR
Both are lit : Measurement center distance ±1 mm
NEAR
Lit : Near distance side within measurement range
FAR
Lit : Far distance side within measurement range
NEAR/FAR
Both are flashing : Beyond measurement range
Figure 3-4-4-1 Adjusting the HMS Height
After the sensor height has been adjusted, input the MS parameters related to the bad mark sensor
offset. For details about how to input MS parameters, see “MS Parameters”.
CAUTION
To prevent any personal injury, do not put your hand inside the
machine or your face or head close to the machine during operation
of the touch panel and/or HOD
.
Rev. 1.00