FX-3R Maintenance Guide
3-3
3-2. Replacing the Filter
Before replacing the filter, always shut-down the main compressed air.
<Replacing the head filter>
1)
Remove the cap bolts
c
(
×
2) and cap bolts
d
(
×
2) to detach the filter box U.
(O-ring is mounted under the filter box U. Carefully handle this O-ring so that it is not lost.)
2)
Take out the filter and replace it with a new one.
3)
Reassemble the parts and components in the reverse order of disassembly.
4) After the filter has been replaced, check the filter through the head vacuum and the blow
ON/OFF of the manual control.
<Replacing the filter for release to atmosphere>
1)
Remove the SEMS cap bolts
e
(
×
2) to detach the SV cover.
2)
Loosen the SEMS cap bolts
f
(
×
2) to detach the filter for release to atmosphere.
(You can detach the filter only by loosening the SEMS cap bolts.)
3)
Reassemble the parts and components in the reverse order of disassembly.
∗
SEMS cap bolts
f
(2 pcs.) are accessory parts supplied with the solenoid valve.
c
Tightening torque: 0.9N
⋅
m
d
SM6034002TN
SEMS cap bolt M3
×
40
d
Tightening torque: 0.6N
⋅
m
E3052729000
Head filter
e
SL6030692TN
SEMS cap bolt with washer
M3
×
6
40068171
Filter for release to
atmosphere
SEMS cap bolt
f
(
×
2)
c
SM6031602TN
SEMS cap bolt M3
×
16
Figure 3-2-1 Replacing the Head Filter
Rev. 1.00