FX-3R Maintenance
Guide
10-3
10-3. Replacing the Cover Open Switch
10-3-1. Switch Main Unit
1)
Disconnect the connector of the switch
c
from the relay connector.
2)
Cut the tie-up band and remove the set screws
d
(SL6042042TN) to replace the switch
c
main unit.
3)
Reassemble the components in the reverse order of disassembly.
After assembling, check to make sure that the assembly has been fit in the safety cover
f
, and
the operation key can be inserted into the switch properly.
∗
After the new switch has been mounted, make sure that the safety cover
f
is mounted
correctly and that the operation key
g
is inserted into the switch correctly.
Rev. 1.00
Viewed from A
c
c
d
c
e
f
g
Viewed
from A
Figure 10-3-1 Replacing the Switch Main Unit
[List of Replacement Parts]
Table 10-3-1 Replacement Parts for Cover Open Switch
No.
Part No.
Part name
Q’ty per machine
c
40002254 COVER_OPEN_SW_CABLE_ASM
8
d
SL6042042TN SEMS
cap
bolt
16
e
NM3040520SF Nut
16
f
40063507 SAFETY_COVER_FRAME
4
g
HA005280010 SAFTY_SWITCH_KEY
8