− 68 −
No.
Item
Setting range
/
Edit unit
Initial value
Clamp foot down order change-over
Lowering order of clamp foot is selected.
- - -
From right
From left
Right/left at the
same time
* When right and left are simultaneously actuated with customizing of
pedal setting, this parameter is neglected and the right and left are
simultaneously actuated.
Folding plate motion mode
“Return/No return” of folding plate when corner knife projects is selected.
- - -
Return
No return
Binder pressure reduction rise prohibition
Pressure reduction rise of the binder at the time of jump feed is prohibited.
- - -
Pressure reduction
rise is prohibited
Pressure reduction
rise
Standing pedal continuous depressing timer effective/ineffective
change-over
Effective/ineffective of
standing pedal continuous depressing
timer is selected.
* It is possible to set only when
one-shot pedal is set.
- - -
※
Ineffective
Effective
Standing pedal continuous depressing timer
When performing sewing product setting work with the standing pedal
depressed, the time interval when the respective devices operate in
order is set.
* It is possible to set only when
one-shot pedal is set.
0.1 to 2.0
/
0.1 sec.
0.5 sec.
※
Condensation/back tack detailed setting
Detailed setting “Perform/Not perform” of pitch of condensation/back
tack section is selected.
- - -
Perform
Not perform
Flap stopper position
In case of flap sewing, sewing start irradiation position of marking light
(distance from needle)is set
* Setting is only the irradiation position of marking light. Actual sewing
position is the flap end position detected by the flap sensor.
80.0 to
280.0
/
0.1mm
80.0mm
※
. . . Item that is not displayed due to other setting state