V:\Mark\AP-F6 Operation Manual.doc
4
JST
AP-F6 PNEUMATIC CRIMPING MACHINE
3. CONTROL BOX CONFIGURATION
3.1 Control Panel and functions
FRONT FACE
1. Main Switch
This rocker switch controls the power
supply to the AP-F6. When the machine
is turned on the pilot lamp illuminates.
Always ensure that the machine is
turned off when it is left unattended for
any reason.
2. Total Counter
This counter displays the total cycles
performed by the AP-F6.
3. Reset Button
This button is depressed to zero the
Total Counter display.
4. ' Fault ' Display (red LED)
This LED illuminates when the air
pressure falls below a pre-set level, or
the Safety Guard is not fitted to the
machine.
5. Input display (red LED)
This LED illuminates whenever the
Touch Sensor or Foot switch are
actuated.
6. Tape Feed Switch
The Tape Feed switch illuminates when
the main switch pilot lamp is on.
The Tape feed switch can only be
operated when the Adjust Switch is in
the UP position.
If an operational error occurs, the Tape
Feed switch will flash on and off.
7. Adjust Switch
This switch is used to move the ram up
or down.
8. Touch Sensor Switch
The Touch Sensor switch should be in
the 'ON' position when the Touch
Sensor is in use.
9. Touch Sensor Input Socket
This is the socket into which the Touch
Sensor plug is connected.