V:\Mark\AP-F6 Operation Manual.doc
14
JST
AP-F6 PNEUMATIC CRIMPING MACHINE
6. INSPECTION OF CRIMPED WIRE
6.1 Checking and adjustment of
crimp position
CAUTION !
Before opening the fabricated
cover to adjust the crimp position,
ensure that the air and electricity
supplies are disconnected.
If the crimp position is not centred
correctly, adjustments are required to
be made to the index wheel position
(part no. 2108-4115-1).
In the case of an insulated terminal,
the insulation should be removed from
the terminal with the aid of a pair of
cutters, to enable the indentation to be
assessed.
The drawings opposite illustrate the
visual appearance of both correctly
and incorrectly crimped terminals.
The adjustment procedure is as
follows:-
Step 1.
Set the Adjust switch to the UP
position.
The ram rises to Top Dead Centre,
and the terminal is free to move
relative to the anvil.
Step 2.
Disconnect both the air and electricity
supplies.