This field is used to set the maximum output voltage of the monitoring signals for both channel A
and channel B, default value is 10V.
If S Monitoring is selected, the maximum output voltage corresponds to the motor rated speed.
If I Monitoring is selected, the maximum output voltage corresponds to the motor 300% rated
current.
If P Monitoring is selected, the maximum output voltage corresponds to the tracking error setting
set in the
“
Motor Parameter
”
menu.
Motor definition rotation
You can choose positive command voltage to CW rotation or CCW rotation.
Select CN1-16 function