22 | Installation
1 Installation
1.1 Operator Stations
The AlphaDynaPos Dynamic Positioning system is a redundant (double) Dynamic Positioning system fulfilling the rules
of IMO DP2.
A DP Console consists of a redundant DP Controller, a redundant DP Workstation, a redundant DP Operator Panel and
a redundant DP Thruster I/O Controller.
•
The redundant DP Controllers are built-up around an extremely robust and highly powerful computer with solid
state disks. The DP Controller has interfaces to the DP Workstation, DP Operator Panel and the DP Thruster I/O
Controller. The DP Controller has up to 21 NMEA and RTCM104 interfaces for Heading, Position, Wind and Motion
Reference Unit sensors.
Note The DP Controller can be bulkhead mounted inside a yard supplied bridge console or can be mounted
in an optional DP Console.
•
The redundant DP Workstations are equipped with a high resolution TFT color screen, a Trackball for operation and
an optional Printer. The DP Workstation is used for DP data presentation in a graphical and user-friendly manner.
Note The DP Workstation can be bulkhead mounted inside a yard supplied bridge console or can be
mounted in an optional DP Console.
•
The redundant DP Operator Panels are equipped with a joystick with heading knob integrated in joystick and with
push buttons for choosing different operator modes and a tracker ball with numeric keyboard.
Note The DP Operator Panel can be bulkhead mounted inside a yard supplied bridge console, or can be
mounted in an optional DP Console.
•
The redundant DP Thruster I/O Controllers can accept any kind of thrusters as can be found in DP applications (e.g.
CPP propellers, rudders, azimuth thrusters, tunnel thrusters etc.).
Note The DP Thruster I/O Controller is mounted in the Thruster I/O Cabinet and provides interfaces to both
DP Controllers.
•
The redundant UPS's powers the AlphaDynaPos DP2 Dynamic Positioning system. A unique feature of the
AlphaDynaPos DP2 system is that it is entirely powered by 24VDC. The UPS has a 230VAC input and a 24VDC fail
safe output with a 30 minutes battery back-up.
1.1.1 Power Distribution Panels
Inside the cabinet are the switches to turn the DP system components on or off.
UPS 1 POWER DISTRIBUTION
UPS 2 POWER DISTRIBUTION
SHIP SUPPLY 24 Vdc
F1
DP-1 (Mounting plate, Panel PC,
joystick)
DP-2 (Mounting plate, Panel PC,
joystick)
JC-SYSTEM (Mounting plate,
Panel PC, joystick)
F2
THRUSTER CONTROLLER
THRUSTER CONTROLLER
F3
DGPS-1
DGPS-2
F4
GYRO-1
GYRO-2
F5
WIND-1
WIND-2
F6
MRU-1
MRU-2
F7
CYSCAN LASER SYSTEM
GYRO-3
F8
Table 2: Power Distribution
Содержание Alphatron Marine AlphaDynaPos
Страница 1: ...AlphaDynaPos Ship Automation and Navigation system Operation Manual www jrc am ...
Страница 5: ...5 Contents 4 2 Appendix B Checklist for Taking DP system into Operation 85 ...
Страница 13: ...13 Introduction III 3 System Overview DP2 Figure 2 system Overview DP2 ...
Страница 14: ...14 Introduction III 4 Sensor Overview Figure 3 Sensor Overview ...