47 | Operation
2.3.6 Position
Information and settings on the position reference sensors can be obtained with the Position tab in the top of the large
screen (Figure 37: Position Screen on page 47).
Figure 37: Position Screen
To select a sensor to be used click the check box in the USE column. Before USE is allowed the sensor must be
calibrated (for example see the ACOUSTIC in the above screen shot). Calibration will be done automatically (after re-
connection), but can also be done manually by clicking on the check box in the CALIB column. The weight of each
sensor is calculated automatically by the deviation of this sensor to the vessel model.
To review the accuracy of each sensor open the PRS PLOT screen by using the tab below the POSITION tab (Figure 38:
PRS PLOT Screen on page 48).