14
5.3.2
The user can start or stop a cycle at any time during the manual
cycle by pressing the START/STOP button. If the Start/Stop button
is pressed, the cycle will be interrupted for 60 minutes or until the
Stop/Start button is pressed. The following message will flash on
the display periodically during the clean cycle:
PRESS START/STOP BUTTON TO HALT
THE START OF THE CLEAN CYCLE
5.3.3
Once the clean cycle has started, the controller will then turn on the
heaters and the following message will be displayed:
MANUAL CLEAN CYCLE IN PROGRESS
HEATERS ON
The heaters will remain on until the grease temperature is 110°F. If
the temperature is not reached in 8 hours the controller LCD
display will indicate an error. Should this error occur, disconnect
power from the unit and call for maintenance.
5.3.4
Once the preset temperature is reached the GI-2000 will pump the
grease out and the following message will be displayed:
MANUAL CLEAN CYCLE IN PROGRESS
PUMP ON XXXX TIME REMAINING
WARNING, DO NOT RUN PUMP DRY!
The GI-2000 has been
pre-calibrated at the factory, prior to shipping, to ensure a suitable
pump time and water sense level. However, if adjustments have
been made it is important to ensure that pump does not run dry!
5.3.5
After the pump cycle is complete, the controller will beep again and
the following message will be displayed:
MANUAL CLEAN CYCLE COMPLETE
5.3.6
After the indication of the cycle being complete the horn will sound
and the unit will wait for the water level in the tank to rise above the
pump inlet. The following message will be displayed:
MANUAL CYCLE COMPLETE
WAITING FOR LEVEL TO RISE
5.3.7
Once the water level rises, the unit display will cycle to the main
manual mode.
MANUAL CYCLE COMPLETE
WAITING FOR LEVEL TO RISE