19
7.5.4.8
It will take the system longer to read the second level of
calibration then the first. After the level of calibration is
read, the following message will be displayed:
LEVEL TWO CALIBRATION
SUCCESSFUL
7.5.4.9
After a few seconds the following message will be
displayed:
CALIBRATION COMPLETE
RETURNING TO NORMAL OPERATION
7.5.4.10
Within a few seconds the system will return to automatic
or manual display modes.
7.5.4.11
It is suggested at this point to check the water level which
should read a minimum of 4.00”. (See Section 6.5 of
Installation Manual)
7.6
SETTING PUMP RUN TIME
7.6.1
Press the CAL/MODE button THREE times and the following
message will be displayed:
PRESS UP/DWN KEYS FOR DESIRED CAL
PRESS ENTER TO SET PUMP ON TIME
7.6.2
After pressing ENTER the following message will be displayed:
USE UP AND DOWN KEYS TO SET PUMP TIME
PRESS ENTER WHEN SET. LEVEL : XX
7.6.3
Use the UP and DOWN arrow keys to set the time ( in seconds)
that the pump should run. The maximum is 400 seconds and the
minimum is 20 seconds.
WARNING!
Do not allow the pump time to
run dry. After the desired time has been set press ENTER and the
system will return to automatic or manual display mode.
7.6.4
It is important to keep a record of the correct pump time in case the
value needs to be re-entered.
8.
CLEAN CYCLE RATE ADJUST MODE
8.1 WHEN
8.1.1
When necessary to easily modify the pumping cycle frequency.
8.2 HOW
8.2.1
Press the CC RATE button once.