16
WARNING, DO NOT RUN PUMP DRY!
The system has been pre-
calibrated at the factory, prior to shipping, to ensure a suitable
pump time and water sense level. However, if adjustments have
been made it is important to ensure that pump does not run dry!
6.3.5
After the pump cycle is complete, the controller will beep again and
the following message will be displayed:
AUTOMATIC CLEAN CYCLE COMPLETE
6.3.6
After the indication of the cycle being complete the horn will sound
and the unit will wait for the water level in the tank to rise above the
pump inlet. The following message will be displayed:
6.3.7
Once the level rises, the unit display will cycle to the main
automatic mode.
7. CALIBRATION
MODE
7.1 WHEN
7.1.1
The calibration mode is intended to enter the date, pump run time
and calibrate the probe for measuring grease. It is important to note
that the probe calibration senses the water level in the tank.
Therefore, the tank should not have any grease introduced into the
system.
The time/date, pump run time and the probe calibration
should typically be checked at a minimum of once a year.
7.2 HOW
7.2.1
Open the controller enclosure and push the CAL/MODE button.
The following message will be displayed:
PRESS UP/DWN KEYS FOR DESIRED CAL
PRESS ENTER TO CHANGE TIME AND DATE
7.3
CANCELLING THE CALIBRATION MODE
7.3.1
Pressing the CANCEL button TWICE at any point during the
calibration mode will exit the calibration mode and revert to the
previous calibration values. Pressing the CANCEL button ONCE
will display the following message:
PRESS CANCEL KEY AGAIN TO EXIT CAL MODE
THIS LINE WILL DISPLAY AS PREVIOUS
AUTOMATIC CYCLE COMPLETE
WAITING FOR LEVEL TO RISE