20
8.3
PROCESS
8.3.1
While in any stage of the CC RATE mode, pressing the CANCEL
key or not pressing any key within 15 minutes will revert the system
to normal operation.
8.3.2
After pressing the ENTER button the following message will be
displayed:
CLEAN CYCLE RATE: XXXXXXXXXXXXXXXXXXXX
USE UP/DN KEY, THEN ENTER TO SELECT RATE
8.3.3
The section shown as xxxx… above, shows the present rate
setting. The available settings are:
LESS OFTEN – HIGH
Water Level Reading of 0.4” will activate “HIGH GREASE ALARM”
LESS OFTEN – MEDIUM
Water Level Reading of 0.9” will activate “HIGH GREASE ALARM”
LESS OFTEN – LOW
Water Level Reading of 1.4” will activate “HIGH GREASE ALARM”
NORMAL
Water Level Reading of 1.9” will activate “HIGH GREASE ALARM”
MORE OFTEN – LOW
Water Level Reading of 2.4” will activate “HIGH GREASE ALARM”
MORE OFTEN – MEDIUM
Water Level Reading of 2.9” will activate “HIGH GREASE ALARM”
MORE OFTEN – HIGH
Water Level Reading of 3.4” will activate “HIGH GREASE ALARM”
If the necessary clean cycle rate cannot be obtained by any of
these settings, re-calibration of the system may be required.
Pressing the UP and DOWN keys allows the user to select one of
the above settings. Once the desired rate is displayed, press the
ENTER key to select it. The following message will be displayed:
RATE SET TO: XXXXXXXXXXXXXX
PRESS ENTER AGAIN TO SAVE.
8.3.4
Press the ENTER key to save the setting or press CANCEL twice
to exit. Once the ENTER key is pressed once the following
message will be displayed:
RATE ADJUST SAVE
8.3.5.
Within a few seconds the system will return to automatic or manual
display mode.