42
2.8 Installing hot air ducting pipes
To fit the hot air pipes proceed as follows:
• Connect the Ø 100 mm aluminium pipes to the collars provided on the top of the stove, under the cladding cover (see example in
F
ig
. 1
), and fix them with the special pipe clamps supplied.
If the change air is not going to be ducted, fix 2 vertical pipes approx.
2 cm long, so that they rest under the top cover of the cladding.
• The two precut sheet disks at the bottom of the stove cladding must be knocked out for the ducts (
F
ig
. 2
).
• One or more branches can be applied for possible ducting to other rooms (see par. 1.14 e 2.9)
• It is advisable to use Y connections.
Example of Fogo stove side panel.
F
ig
. 1
NOTE!
It is advisable to knock out the precut disk at the bottom
(indicated by the arrow) to connect the hot air fan pipe to the
outside of the cladding.
That indicated also applies for the Foghea stove.
F
ig
. 1
existing
openings
precut
Содержание FOGHEA
Страница 46: ...46 Notes...