background image

Combined wood/pellet version 
Curved or straight front
JOLLY ME 07 F patented burner
Automatic lighting

INSTALLATION, USE

AND MAINTENANCE CARD

To be carefully kept by the purchaser

FOGO

Cladding of Foghet with curved or straight front

FOGHEA

Cladding of Foghet with straight front

Humidified air 

heating

FOGO and 

FOGHEA

Содержание FOGHEA

Страница 1: ...ME 07 F patented burner Automatic lighting INSTALLATION USE AND MAINTENANCE CARD To be carefully kept by the purchaser FOGO Cladding of Foghet with curved or straight front FOGHEA Cladding of Foghet...

Страница 2: ...his technical sheet are owned by JOLLY MEC CAMINETTI S p A The descriptions and illustrations provided in the following publication are not binding JOLLY MEC CAMINETTI S p A reserves the right to make...

Страница 3: ...rmostat 17 1 7 13 Lighting in wood mode 19 1 7 14 Service 20 1 8 Optimising combustion and damper use 21 1 9 Advice and instructions 22 1 10 Cleaning the stove 23 1 11 Parts that can be removed to cle...

Страница 4: ...the Jolly Mec patented Caldo Control system which optimises combustion according to combustion air temperature WithapplicationofthespecificJOLLYME 07 Fpelletburner FOGO and FOGHEA become continuous f...

Страница 5: ...erials Warnings This plate is positioned on the right side of the stove The graphic appearance of the dataplate can be different Pursuant to European Regulation No 305 2011 manufacturers are now requi...

Страница 6: ...let Bt 4 7 Kg h 303 Consumption at med power by pellet 3 6 Kg h 304 Consumption at min power by pellet 2 9 Kg h 305 Consumption in economy power by pellet 0 1 Kg h 357 Maximum output disposed of in th...

Страница 7: ...ir fan suction from the outside 80 mm flexible pipe 50 cm long not extensible for burner fan suction from outside 80 mm flexible pipe 100 cm long extensible for primary combustion air suction from out...

Страница 8: ...urved or straight front and stove cladding Curved front Foghet with FOGO stove cladding Foghet with straight front and FOGHEA stove cladding Cladding weight FOGO 103 kg Total weight FOGO 293 kg Claddi...

Страница 9: ...support fixed to the burn pot container when fixing with the screws the flange must protrude approx 2 mm with respect to the face of the assembly plate Standard pellet hopper Level sensor simplified e...

Страница 10: ...t burn properly the burn pot can be manually cleaned two or three times in a row LEDs BUTTONS Quick Menu for the various operation stages and programming Manual pellet loading and burn pot cleaning Ch...

Страница 11: ...ng LED must be on 10 If the electronic controller is in wood mode set it to pellet mode by pressing the corresponding button 11 Check that there are pellets in the hopper otherwise top up with pellets...

Страница 12: ...s up The burner is managed with the room temperature probe on reaching the set room temperature it switches to the economy mode the display shows the message ECON and restarts when the room temperatur...

Страница 13: ...s having different characteristics 00 SET PELLET Max 20 Min 10 Setting combustion air in wood mode 0 SET AIR WOOD Max 35 Min 0 20 SET AIR FAN SPEED Max 35 Min 1 Setting automatic or manual fan operati...

Страница 14: ...llet mode the stove can be set to the following power levels which are shown on the display 1 7 6 Setting room temperature in pellet mode To maintain the required room temperature the Foghet is equipp...

Страница 15: ...since the spilling of excess water can damage the fan 1 7 8 Summer ventilation To use the stove for summer ventilation of rooms proceed as follows Switch on the electronic controller by pressing ON Pr...

Страница 16: ...onic component test Switch off the electronic controller by pressing OFF Press the button TEST holding it down for a few seconds the electronic controller will activate the selected part Check the par...

Страница 17: ...y 07 31 SET HOURS DAY CHRONOTHERM EXCLUDED CHRONOTHERMOSTAT Programme 01 Mo Tu We Th Fr Sa Su ON 06 00 OFF 09 30 Programme setting hourly weekly 1 Press to exit the operation status screen CHRONOTHERM...

Страница 18: ...et End of chronothermostat setting operation Chronothermostat activation or deactivation 10 Press and with the selected programme number flashing keep pressed until the set lighting days are reset To...

Страница 19: ...er starts automatically after 30 minutes For correct operation in wood mode it is suggested to set SET AIR WOOD function to the value 2 in the Quick menu Fireplace output and load burn time are regula...

Страница 20: ...obal working hours In the QUICK MENU a voice HOUR COUNTER has been add and it visulises To reset the signal for ordinary maintenance hours in the VISUALISATION MENU enter the quick menu and press butt...

Страница 21: ...nical data set the electronic controller to medium power close the damper and the Caldo Control set the combustion air and the pellets to 0 The flame should be as in Fig 4 While burning the pellets mu...

Страница 22: ...aded in the hopper check and remove any sawdust deposited on the bottom sawdust reduces in feed screw capacity and creates stove operation problems The firebox must always be closed except when loadin...

Страница 23: ...st Fig 3 and then reposition it as per Fig 1 while ensuring that the locking lever is well hooked in its slot Cleaning the glass When using the fireplace in pellet mode clean the glass every day with...

Страница 24: ...e stove 24 Cleaning tools supplied Burn pot cleaning tool Poker Shovel Flue brush Small brush 1 2 3 4 5 6 Cast iron grates Pellet burn pot Ash pan Smoke baffle Fire bed Wood guard and removable door s...

Страница 25: ...causing noise and or problems After removing these parts the stove appears as in Fig 1 8 Remove the plate under the ash pan after undoing the fixing screws Fig 1 9 Detach the fan electrical connectio...

Страница 26: ...nction in the Quick Menu At minimum power the fireplace always goes off because not enough pellets are fed Too much sawdust on the bottom of the hopper Empty the hopper and refill with new pellets eve...

Страница 27: ...aulty or not properly connected Check the connection or replace the probe Room probe Room temperature probe faulty or not properly connected Check the connection or replace the probe Ignition attempt...

Страница 28: ...he hole in the burn pot and in the hopper are aligned 8 Press the button to manually load the fireplace until the pellets start entering 9 Before pressing the ignition button make sure the burn pot is...

Страница 29: ...Universal flue connection 8 150 mm double wall flexible stainless steel flue 9 150 mm smooth stainless steel flue 10 MF connection for 150 mm double wall flexible pipe 11 Joint for 100 mm aluminium p...

Страница 30: ...TE Max conveyance distance 20 metres Max height 6 metres Larger capacity pellet hopper 100 l 400 l or 700 l Pellet hopper with in feed screw Example with larger capacity pellet hopper placed in a room...

Страница 31: ...NETTI S p A recommends using the same type of pellets as those used to test the stove as combustion parameters vary from pellets to pellets JOLLY MEC CAMINETTI S p A declines any liability for malfunc...

Страница 32: ...the time the stove was marketed The Manufacturer reserves the right to make changes to the stove and consequently to the relevant card without having to update previous editions The user can always re...

Страница 33: ...may be dispersed as fertilizer for plants or your garden not exceeding annually 2 6 kg on the 10m The disposal of the machine must comply with current laws and environment RESPECT THE ENVIRONMENT 1 18...

Страница 34: ...p is advisable If the flue is installed externally it must be insulated to prevent the cooling of fumes and the formation of condensate The same applies to the section from the roof to the chimney cap...

Страница 35: ...ase it is not fitting the requirements than take necessary actions ex charge distribution plate The machine has to be installed to be easely cleaned smoking pipes and chimney easely reached and cleane...

Страница 36: ...the cladding must be handled with particular care whether satin finished polished or painted as they could be scratched or dented during handling and assembly It is advisable to handle the various pa...

Страница 37: ...e 4 M6 screws to the right column in the inner counterfold and secure the sides at the rear with 2 M6 screws 10Insert the damper rod in the special hole on the right side inside the inspection door 11...

Страница 38: ...tched or dented during handling and assembly IT is advisable to handle the various parts of the cladding without removing them from the original packing NOTE The flue must be installed in such a way t...

Страница 39: ...screws on the outside and 4 M6 screws on the opposite side 6 Position the right panel on the frame 1 on the folds provided securing it with 3 M6 screws on the outside and 4 M6 screws on the opposite...

Страница 40: ...By assembling take care to position the damper lever in the centre of the chimney The damper is laterally mounted putting the rod into the pre positioned hole in the display holder box Fasten the sup...

Страница 41: ...2 all the way to close the air inlet The Caldo Control can be adjusted after a settling stage by operating the adjustment screw Fig 6 Fig 1 Fig 2 Fig 3 Wood mode pull the lever in the direction of th...

Страница 42: ...hat they rest under the top cover of the cladding The two precut sheet disks at the bottom of the stove cladding must be knocked out for the ducts Fig 2 One or more branches can be applied for possibl...

Страница 43: ...3 cm for the entire length Caution Avoid contact of the pipes with wood and flammable materials Using plastic pipes to deliver the air is very dangerous because the high temperatures could deform them...

Страница 44: ...hot air recirculation compulsory rear suction outside air inlet recommended burner fan air suction Caldo Control air hot air recirculation With the system of air ducted in other rooms it is advisable...

Страница 45: ...bustion air fan Supplementary pellet hopper see Auger or pneumatic conveyance assembly card Electrical connections must be carried out by skilled personnel according to the regulations in force CE 200...

Страница 46: ...46 Notes...

Страница 47: ...47 Notes...

Страница 48: ...SM013 GB REV13 2015_03 Via S Giuseppe 2 24060 Telgate BG ITALIA Tel 39 035 8359211 Fax 39 035 833389 www jolly mec it info jolly mec it...

Отзывы: