background image

19

ENGLISH

1

.  Airtight steel sheet 

metal

2

.  45° Curves

3

.  Fume exhaust

4

.  External insulated flue

5

.  Insulated T union for 

condensation

6

.  Non-insulated pipe

 

07.2 

FLUE OR FUME EXHAUST SYSTEM

The flue or fume exhaust system is a fundamental element for the proper functioning of the stove and must comply with the following 

general standards:
EN1856-1 

Chimneys. Requirements for metal chimneys - Part 1: System chimney products

EN1856-2  

Chimneys. Requirements for metal chimneys - Part 2: Metal flue liners and connecting flue pipes

UNI 10683  

Heat generators operating with wood or other solid bio fuels - Installation requirements

The diameter of the flue must be sized according to the technical specifications of the appliance and type and place of installation. Each

appliance must have its own chimney flue without any inlets from other appliances.

The exhaust duct of the combustion products generated by the forced draught equipment must respond to the following requirements:

• 

it is necessary to use union joints and pipes with pressure resistant seals, as the union of the flue could be slightly pressurised 

while the appliance running

• 

all changes in direction must be open to inspection to facilitate maintenance

• 

correct draught to maintain depression in the combustion chamber, as per the technical specifications, must be guaranteed

• 

it must be watertight, waterproof and suitably isolated and insulated

• 

must be made of suitable materials that resist normal mechanical stress, heat, the action of the combustion products and acid 

condensations

• 

must be prevailingly vertical structures with deviations from the axis not greater that 45°

• 

must be adequately distanced from combustible or inflammable materials via an air space or suitable insulation

• 

must have an internal section which is preferably circular: square or rectangular sections must have rounded corners with a 

radius of no less than 20 mm

• 

must have an internal section that is constant, free and independent

If the flue is installed externally it must be insulated to prevent the cooling of fumes and formation of condensation. The same is valid for 

the tract from the roof to the chimney cap (Torrino). For the union between the stove and the flue, or if there are deviations or curves, for 

easier, quicker and safer installation, we recommend using double-walled stainless steel pipes. 

The use of pipes in fibre cement for connecting the equipment to the flue is forbidden.

Exhaust pipes must not run through rooms where the installation of combustion equipment is forbidden. The union must be connected 

to the flue in such a way as to ensure they remain airtight when the appliance is operating in pressurised conditions and to avoid the 

formation of condensation and its conveyance to the appliance.

It has to be avoid, as much as possible, the assembly of 

horizontal sections. In any case, the horizontal segment (or its 

horizontal projection) do not have to be longer than two meters 

with minimum slope not less than 5%. The horizontal section 

does not have to be connected directly to the smoke fan output 

but after the first vertical segment (6) 

Fig.1.

The  chimney  system  for  the  smoke  exhaust  MUST  be 

dimensioned  and  projected  by  a  Qualified  Engineer. 

He  will  determine  the  proper  smoke  exhaust  system 

taking into consideration the product technical data, 

kind  of  installation,  installation  location  and  mostly  the 

installation  technical  regulation  in  force.  The  Engineer 

will give indications to the installer about the materials to 

use, smoke path section, insulation thickness, corrosion 

resistance  and  all  requirements  needed  for  the  correct 

working of the system product-chimney.
The correct dimension of the air intake for ventilation and 

aeration of the installation location MUST be verified in 

conformity with the technical regulation in force.
Malfunctioning of the product caused by a smoke exhaust 

not  properly  projected  and  dimensioned  WILL  NOT  be 

object of objections to Jolly-Mec and interventions at Jolly 

Mec charge.

For appliance that must reach ceiling or wall exhaust outlets 

that are not coaxial with regard to the issue of the fumes from 

the machine, changes in direction must be made using an open 

elbow of 45° (see 

Fig.1

).

The use of counter slope elements is forbidden. The flue union 

must have a constant section and allow soot to be collected and 

swept away. Changes in cross-section are only allowed at the 

outlet of the heat generator: the use of adaptors on the coupling 

with the chimney flue is prohibited.

Running other air ducts and installation pipes inside the exhaust 

pipes, even if oversized, is forbidden.

Fig.1

2

3

1

4

2

5

6

1,5 m min.

1,5 m min.

Содержание AMBRIA2

Страница 1: ...SM122 EN REV06 2021_06 AMBRIA2 6 kW AMBRIA2 8 kW INSTALLATION USE AND MAINTENANCE MANUAL To be kept by the purchaser Pellet operated air heating stove AMBRIA2...

Страница 2: ...y read and keep this sheet before using the equipment This sheet provides necessary information and suggestions on how to correctly install use clean and maintain the product Knowing and observing the...

Страница 3: ...CHAP 05 DESCRIPTION 12 05 1 PRODUCT PRESENTATION 12 05 2 PRODUCT IDENTIFICATION 13 CHAP 06 TECHNICAL DATA 14 06 1 HOMOLOGATION 14 06 2 RECOMMENDED FUELS 15 06 3 COMPONENTS 16 06 4 DIMENSIONS 17 CHAP 0...

Страница 4: ...more restrictive in this instance comply fully with the regulations prevailing in the country of installation all laws and local bylaws must be observed when installing and using the appliance includ...

Страница 5: ...old electrical appliances and similar products General safety regulations EN 60335 2 102 Safety of household electrical appliances and similar products Special regulations for appliances fitted with g...

Страница 6: ...right to make modifications to the product and consequently the relative manual without any obligation to update previous editions 01 5 MANUFACTURER LIABILITY AND WARRANTY CONDITIONS Upon the delivery...

Страница 7: ...ensory or mental capabilities or lacking the experience or the needed knowledge can use the device only under surveillance or having been instructed on the device safe use and on the understanding of...

Страница 8: ...ce with the laws and standards in force in the State Region or Area in which the machine is installed Installation in bedrooms rooms with a volume below 15 m3 or with explosive atmospheres is strictly...

Страница 9: ...urs of operation shall be reset at the end of the Technical intervention and indicated on the Servicing Report 02 4 EQUIPMENT FOR OPERATORS AND MAINTENANCE PERSONNEL Every operator performing maintena...

Страница 10: ...03 2 LIFTING AND TRANSPORT Personnel in charge of handling the product must have read and thoroughly understood the safety prescriptions in CHAP 02 ACCIDENT PREVENTION SAFETY REGULATIONS of this manu...

Страница 11: ...rective 2012 19 UE waste electrical and electronic equipment WEEE information for users The crossed out wastebasket symbol on the appliance means that at the end of its useful lifespan the product mus...

Страница 12: ...l with Display Wide backlit LCD display allowing operators to interface with the product set the operating parameters and receive work status data Timer controlled thermostat used to set the start up...

Страница 13: ...O Tensione Frequenza nominale Rated voltage frequency Spannung Nennfrequenz Tension Fr quence nominale Tensi n Frecuencia nominal Temperatura dei fumi Flue gas temperature Abgastemperatur Temp rature...

Страница 14: ...Switching on nominal power reduced power stand by 310 60 15 2 2 310 65 15 2 2 W Device mass 110 110 Kg Standard hopper capacity 15 15 Kg Flue draught Nominal heat output Reduced heat output 10 0 8 0...

Страница 15: ...use pellets that are very hard and with different dimensions the mechanical parts are sized and tested for use with pellets with the above mentioned characteristics No breakdown or malfunction depend...

Страница 16: ...r loading pellets 4 Emergency console 5 Firebox 6 Ash drawer 7 Combustion chamber door 8 Pellet hopper 9 Electronic control unit 10 Fume pressure switchi 11 Comburent air inlet tube 50 mm 12 Room temp...

Страница 17: ...17 ENGLISH 06 4 DIMENSIONS All measurements are in mm AMBRIA2 6 kW AMBRIA2 8 kW A 461 5 B 1073 C 487 8 AMBRIA2 6 kW AMBRIA2 8 kW C A B...

Страница 18: ...exhaust pipes and flue can be easily accessed for maintenance Fig 1 illustrates minimum distances that must be observed all measures must be in mm The lateral distance from the adjacent wall according...

Страница 19: ...re are deviations or curves for easier quicker and safer installation we recommend using double walled stainless steel pipes The use of pipes in fibre cement for connecting the equipment to the flue i...

Страница 20: ...hand the purchaser MUST assign all work to a qualified professional technician The device must be installed and used in accordance with all local and national laws and EC Regulations WARNING In the e...

Страница 21: ...opening needs to be designed in compliance with the specifications in paragraph 07 3 4 All models may be connected to the fume pipes with rear fume outlet Fig 1 For the construction of fume pipes plea...

Страница 22: ...force 2014 30 UE and 2014 35 UE WARNING Number Description 1 Radio control 2 Electronic card 3 Bipolar switch 4 Electric power cord with schuko socket 5 Smoke fan 6 Electrical heating element 7 Excha...

Страница 23: ...ontrol unit connected by radio frequency to the radio remote control manages all the device functions and the LCD display screen on the handheld console can be used to monitor all the stove operating...

Страница 24: ...ET ambient temperature which correspond to the automatic start up value of the stove In this condition the stove is not actually off but is waiting to turn back on if the above conditions are satisfie...

Страница 25: ...Wait until the appliance is completely cold on average 20 minutes 2 Unscrew the thermostat reset button lid on the back of the appliance see Fig 1 positions B 3 Press the button until you hear a CLIC...

Страница 26: ...hopper using a scoop Do not empty the sack directly into the hopper Check for obstructions in the flue and in the external air intake before starting the machine after a prolonged period of disuse Th...

Страница 27: ...use an ash vacuum not supplied with the stove but available from retailers and or specialised Technical Service Centers ORDINARY CLEANING THE INSTRUCTIONS BELOW REGARDING THE TIMING AND METHODS USED...

Страница 28: ...rnal walls and shaking it eventually Before replacing the firebox check there is no ash or dirt in the firebox housing Vacuum this area thoroughly too make sure residual ashes are cold Fig 8 Make sure...

Страница 29: ...Never spray detergents directly on cladding parts Fig 22 Use of abrasive and or corrosive chemical products can damage the painted parts and are reason for invalidation of the warranty on these parts...

Страница 30: ...into the domestic electrical system turn the switch to I see Fig 28 10 Pellet hopper loading Located on the rear part of the device the hopper is filled through an openable lid The hopper must be fill...

Страница 31: ...th special focus on horizontal segments Stove fume pass cleaning Cleaning of any deposits in the stove Cleaning of fans Check good ignition resistance operations Check electric electronic system integ...

Страница 32: ...at and pressure switch status and efficiency T Check the condition of the sealing gaskets paying special attention to the one on the closure of the combustion chamber door T Check the condition of the...

Страница 33: ...s safety pressure switch The stove does not start automatically The firebox is dirty preventing incoming air flow Clean it thoroughly and check it is clean each time you start it up The basket is posi...

Страница 34: ...34 NOTES...

Страница 35: ...35 ENGLISH NOTES...

Страница 36: ...SM122 EN REV06 2021_06 Via S Giuseppe 2 24060 Telgate Bg Italy Tel 39 035 83 59 211 Fax 39 035 83 59 203 www jolly mec it info jolly mec it...

Отзывы: